Chapter 4 Explanation of Functions
Register
Function name
No.
1354h
(Reserved)
1355h
Start frequency adjustment
1356h
Carrier frequency setting
Initialization mode (parameters
1357h
or trip history)
1358h
Country code for initialization
Frequency scaling conversion
1359h
factor
135Ah
STOP key enable
135Bh
Restart mode after FRS
135Ch
(Reserved)
135Dh
Dynamic braking usage ratio
135Eh
Stop mode selection
135Fh
Cooling fan control
1360h
(Reserved)
1361h
(Reserved)
1362h
Dynamic braking control
1363h
Dynamic braking activation level
1364h
(Reserved)
Thermistor for thermal protection
1365h
control
1366h
Thermal protection level setting
1367h
Free-setting V/f frequency (1)
1368h
Free-setting V/f voltage (1)
1369h
Free-setting V/f frequency (2)
136Ah
Free-setting V/f voltage (2)
136Bh
Free-setting V/f frequency (3)
136Ch
Free-setting V/f voltage (3)
136Dh
Free-setting V/f frequency (4)
136Eh
Free-setting V/f voltage (4)
136Fh
Free-setting V/f frequency (5)
1370h
Free-setting V/f voltage (5)
1371h
Free-setting V/f frequency (6)
1372h
Free-setting V/f voltage (6)
1373h
Free-setting V/f frequency (7)
1374h
Free-setting V/f voltage (7)
1375h to
(Reserved)
137Ah
1383h
(Reserved)
1384h
(Reserved)
1385h
Overvoltage suppression enable
1386h
Overvoltage suppression level
Acceleration and deceleration
1387h
rate at overvoltage suppression
Overvoltage suppression
1388h
propotional gain
Overvoltage suppression Integral
1389h
time
1390h to
(Reserved)
1400h
Function
R/W
Monitoring and setting items Data resolution
code
-
-
Inaccessible
b082
R/W 10 to 999
b083
R/W 5 to 120 (5 to 80 :90 to 160kW)
0 (clearing the trip history), 1 (initializing the data), 2
b084
R/W
(clearing the trip history and initializing the data)
b085
R/W 0 (Japan), 1 (EU), 2 (U.S.A.)
b086
R/W 1 to 999
b087
R/W 0 (enabling), 1 (disabling), 2 (disabling only stop)
0 (starting with 0 Hz), 1 (starting with matching
b088
R/W
frequency), 2 (starting with active matching
frequency)
-
-
Inaccessible
b090
R/W 0 to 1000
b091
R/W 0 (deceleration until stop), 1 (free-run stop)
0 (always operating the fan), 1 (operating the fan only
b092
R/W
during inverter operation [including 5 minutes after
power-on and power-off])
-
-
Inaccessible
-
-
Inaccessible
0 (disabling), 1 (enabling [disabling while the motor is
b095
R/W
stopped]), 2 (enabling [enabling also while the motor
is stopped])
b096
R/W 330 to 380, 660 to 760
-
-
Inaccessible
0 (disabling the thermistor), 1 (enabling the thermistor
b098
R/W
with PTC), 2 (enabling the thermistor with NTC)
b099
R/W 0. to 9999.
b100
R/W 0. to "free-setting V/f frequency (2)"
b101
R/W 0. to 8000
b102
R/W 0. to "free-setting V/f frequency (3)"
b103
R/W 0. to 8000
b104
R/W 0. to "free-setting V/f frequency (4)"
b105
R/W 0. to 8000
b106
R/W 0. to "free-setting V/f frequency (5)"
b107
R/W 0. to 8000
b108
R/W 0. to "free-setting V/f frequency (6)"
b109
R/W 0. to 8000
b110
R/W 0. to "free-setting V/f frequency (7)"
b111
R/W 0. to 8000
b112
R/W 0. to 400.
b113
R/W 0. to 8000
-
-
Inaccessible
-
-
Inaccessible
-
-
Inaccessible
0 (disabling), 1 (enabling), 2 (enabling with
b130
R/W
acceleration)
200 V class: 330 to 390 (V)
b131
R/W
400 V class: 660 to 780 (V)
b132
R/W 10 to 3000
b133
R/W 0 to 255
b134
R/W 0 to 65535
-
-
Inaccessible
4 - 136
Register
No.
-
0.01 [Hz]
0.1 [kHz]
-
-
0.1
-
-
-
0.1 [%]
-
-
-
-
-
1. [V]
-
-
1. [ ]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
1 [Hz]
0.1 [V]
-
-
-
-
1 [V]
0.01
[sec.]
0.01
0.001
[sec.]
-

Hide quick links: