Chapter 8 List of Data Settings
Code
Function name
Operation mode on expansion card
P001
1 error
Operation mode on expansion card
P002
2 error
Temperature compensation
P025
thermistor enable
P031
Accel/decel time input selection
P044
DeviceNet comm watchdog timer
Inverter action on DeviceNet comm
P045
error
DeviceNet polled I/O: Output
P046
instance number
DeviceNet polled I/O: Input instance
P047
number
Inverter action on DeviceNet idle
P048
mode
DeviceNet motor poles setting for
P049
RPM
P055
Pulse-string frequency scale
Time constant of pulse-string
P056
frequency filter
P057
Pulse-string frequency bias
P058
Pulse-string frequency limit
Easy sequence user parameter
P100
U (00)
Easy sequence user parameter
P101
U (01)
Easy sequence user parameter
P102
U (02)
Easy sequence user parameter
P103
U (03)
Easy sequence user parameter
P104
U (04)
Easy sequence user parameter
P105
U (05)
Easy sequence user parameter
P106
U (06)
Easy sequence user parameter
P107
U (07)
Easy sequence user parameter
P108
U (08)
Easy sequence user parameter
P109
U (09)
Easy sequence user parameter
P110
U (10)
Easy sequence user parameter
P111
U (11)
Easy sequence user parameter
P112
U (12)
Easy sequence user parameter
P113
U (13)
Easy sequence user parameter
P114
U (14)
Easy sequence user parameter
P115
U (15)
(Note)<>indicate the setting range of 90 to 160kW
Monitored data or setting
00 (tripping), 01 (continuing operation)
00 (tripping), 01 (continuing operation)
00 (no compensation), 01 (compensation)
00 (digital operator), 01 (option 1), 02 (option 2), 03 (easy sequence)
0.00 to 99.99 (s)
00 (tripping), 01 (tripping after decelerating and stopping the motor),
02 (ignoring errors), 03 (stopping the motor after free-running),
04 (decelerating and stopping the motor)
20, 21, 100
70, 71, 101
00 (tripping), 01 (tripping after decelerating and stopping the motor),
02 (ignoring errors), 03 (stopping the motor after free-running),
04 (decelerating and stopping the motor)
0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38 (poles)
1.0 to 50.0 (kHz)
0.01 to 2.00 (s)
-100. to +100. (%)
0. to 100. (%)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
0. to 9999., 1000 to 6553 (10000 to 65535)
8 - 14
Setting
Change
Default
during
during
operation
operation
Page
(allowed
(allowed
_FF
or not)
or not)
00
4-82
00
00
4-89
00
4-10
1.00
01
21
71
01
0
25.0
0.10
4-96
0.
100.
0.
0.
0.
0.
0.
0.
0.
0.
4-97
0.
0.
0.
0.
0.
0.
0.
0.

Hide quick links: