Hitachi L700 SERIES Instruction Manual page 204

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Chapter 4 Explanation of Functions
Register
Function name
No.
Operation mode on expansion card
1601h
1 error
Operation mode on expansion card
1602h
2 error
1603h to
(Reserved)
160Ah
Temperature compensation
1619h
thermistor enable
161Eh
(Reserved)
161Fh
Accel/decel time input selection
162Bh
(Reserved)
162Ch
(Reserved)
162Dh
(Reserved)
162Eh
DeviceNet comm watchdog timer
Inverter action on DeviceNet comm
162Fh
error
DeviceNet polled I/O: Output
1630h
instance number
DeviceNet polled I/O: Input instance
1631h
number
Inverter action on DeviceNet idle
1632h
mode
Function
R/W
Monitoring and setting items Data resolution
code
P001
R/W 0 (tripping), 1 (continuing operation)
P002
R/W 0 (tripping), 1 (continuing operation)
-
-
Inaccessible
P025
R/W 00 (no compensation), 01 (compensation)
-
-
Inaccessible
0 (digital operator), 1 (option 1), 2 (option 2),
P031
R/W
3 (easy sequence)
-
-
Inaccessible
-
-
Inaccessible
-
-
Inaccessible
P044
R/W 0 to 9999
0 (tripping),
1 (tripping after decelerating and stopping the
motor),
P045
R/W
2 (ignoring errors),
3 (stopping the motor after free-running),
4 (decelerating and stopping the motor)
P046
R/W 20, 21, 100
P047
R/W 70, 71, 101
0 (tripping),
1 (tripping after decelerating and stopping the
motor),
P048
R/W
2 (ignoring errors),
3 (stopping the motor after free-running),
4 (decelerating and stopping the motor)
4 - 142
Register
No.
-
-
-
-
-
-
-
-
-
0.01 [sec.]
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents