Hitachi L700 SERIES Instruction Manual page 251

L700 series
Hide thumbs Also See for L700 SERIES:
Table of Contents

Advertisement

Code
Function name
C001
Terminal [1] function (*2)
C002
Terminal [2] function
C003
Terminal [3] function (*2)
C004
Terminal [4] function
C005
Terminal [5] function
C006
Terminal [6] function
C007
Terminal [7] function
C008
Terminal [8] function
C011
Terminal [1] active state
C012
Terminal [2] active state
C013
Terminal [3] active state
C014
Terminal [4] active state
C015
Terminal [5] active state
C016
Terminal [6] active state
C017
Terminal [7] active state
C018
Terminal [8] active state
C019
Terminal [FW] active state
*2
When the emergency stop function is enabled (SW1 = ON), "18" (RS) and "64" (EMR) are forcibly written to parameters "C001" and "C003", respectively. (You cannot
arbitrarily write "64" to "C001".) If the SW1 signal is turned off and then turned on, "no" (no assignment) is set in parameter "C003".
Monitored data or setting
01 (RV: Reverse RUN), 02 (CF1: Multispeed 1 setting),
03 (CF2: Multispeed 2 setting), 04 (CF3: Multispeed 3 setting),
05 (CF4: Multispeed 4 setting), 06 (JG: Jogging),
07 (DB: external DC braking),
08 (SET: Set 2nd motor data), 09 (2CH: 2-stage acceleration/deceleration),
11 (FRS: free-run stop), 12 (EXT: external trip),
13 (USP: unattended start protection), 14: (CS: commercial power source
enable), 15 (SFT: software lock), 16 (AT: analog input voltage/current select),
17 (SET3: 3rd motor control), 18 (RS: reset),
20 (STA: starting by 3-wire input), 21 (STP: stopping by 3-wire input),
22 (F/R: forward/reverse switching by 3-wire input), 23 (PID: PID disable),
24 (PIDC: PID reset), 26 (CAS: control gain setting),
27 (UP: remote control UP function),
28 (DWN: remote control DOWN function),
29 (DWN: remote control data clearing), 31 (OPE: forcible operation),
32 (SF1: multispeed bit 1), 33 (SF2: multispeed bit 2),
34 (SF3: multispeed bit 3), 35 (SF4: multispeed bit 4),
36 (SF5: multispeed bit 5), 37 (SF6: multispeed bit 6),
38 (SF7: multispeed bit 7), 39 (OLR: overload restriction selection),
40 (TL: torque limit enable), 41 (TRQ1: torque limit selection bit 1),
42 (TRQ2: torque limit selection bit 2), 43 (PPI: P/PI mode selection),
46 (LAC: LAD cancellation),
50 (ADD: trigger for frequency addition [A145]),
51 (F-TM: forcible-terminal operation),
53 (KHC: cumulative power clearance),
56 (MI1: general-purpose input 1), 57 (MI2: general-purpose input 2),
58 (MI3: general-purpose input 3), 59 (MI4: general-purpose input 4),
60 (MI5: general-purpose input 5), 61 (MI6: general-purpose input 6),
62 (MI7: general-purpose input 7), 63 (MI8: general-purpose input 8),
64(EMR: Emergency stop signal),65 (AHD: analog command holding),
74 (PCNT: pulse counter), 75 (PCC: pulse counter clear),
no (NO: no assignment)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
00 (NO) / 01 (NC)
8 - 9
Chapter 8 List of Data Settings
Default
_FF
18
(*2)
16
03
(*2)
02
01
06
11
13
00
00
00
00
00
00
00
00
00
Setting
Change
during
during
operation
operation
Page
(allowed
(allowed
or not)
or not)
4-47