Input Power Led Is Extinguished; System Fault Led Is Illuminated; Power-On Self Test Diagnostics - Qlogic SANbox 3810 Installation Manual

Fibre channel switch
Hide thumbs Also See for SANbox 3810:
Table of Contents

Advertisement

Diagnostics/Troubleshooting

Power-On Self Test Diagnostics

Input Power LED Is Extinguished

The Input Power LED illuminates to indicate that the switch logic circuitry is
receiving proper voltages. If the Input Power LED is extinguished, do the
following:
1.
Inspect the power cords and connectors. Is the cord unplugged? Is the cord
or connector damaged?
2.
Inspect the AC power source. Is the power source delivering the proper
voltage?

System Fault LED Is Illuminated

The System Fault LED illuminates to indicate that a fault exists in the switch
firmware or hardware. If the System Fault LED illuminates, check the Heartbeat
LED for an error blink pattern and take the necessary actions. Refer to
LED Blink Patterns" on page
Power-On Self Test Diagnostics
The switch performs a series of tests as part of its power-up procedure. The
POST diagnostic program performs the following tests:
Checksum tests on the boot firmware in Programmable Read Only Memory
(PROM) and the switch firmware in flash memory
Internal data loopback test on all ports
Access and integrity test on the Application Specific Integrated Circuit
(ASIC)
During the POST, the switch logs any errors encountered. Some POST errors are
critical, others are not. The switch uses the Heartbeat LED and the Logged-In
LED to indicate switch and port status. A critical error disables the switch so that it
will not operate. A non-critical error allows the switch to operate, but disables the
ports that have errors. If two or more ports fail the POST, the entire switch is
disabled. Whether the problem is critical or not, contact your authorized
maintenance provider.
4-2
Yes - Make necessary corrections or repairs. If the condition remains,
continue.
No - Continue.
Yes - Contact your authorized maintenance provider.
No - Make the necessary repairs. If the condition remains, contact your
authorized maintenance provider.