Tools And Parts; Electrical Requirements; Gas Supply Requirements - Maytag BRAVOS MGD6600TQ0 Use & Care Manual

Steam fabric care system gas dryer
Table of Contents

Advertisement

Available languages

Available languages

:;i_i;;;;;;;;;;;;;;;;;;;;;;;;;;;;i!iii_iiiiIi!iiiiIi!iiiiIi!iiiiIi!iiiiIi!iiiiIi!iiiiIi!iiiiIi!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiiii!iiiii_iii!i:iii!_!_!_!_!_i!!ii!_i!_!_!_!_!_i!;_ii!_i!ii!!_!_!_!_!!!!!_@:i_!;i_!!!ii:;>_!_i_!;i_!_i!!!!!!
iiiiiii_, ¸ !!_!_!_!_!_!_i!;_ii!_i!_ii!;_!_!_!_!_@i1!_!_!_!_!!_!Ii@_!!!iii!i:i;!!_i!!ii@ii!!_!_i!;_ii!_;_!ii!ii!;_!_!!i!!:!ii_iiii_iXi_i_i_i!i!iiiii_i_i_i_i_i_i_i_i_i_i_
¸i;
INSTALLATION
INSTRUCTIONS
Gather the required
tools and parts before starting
installation.
Read and follow
the
instructions
provided
with
any tools listed here.
8" or 10' pipe wrench
8" or 10' adjustable
wrench
(for gas
connections)
Flat-blade
screwdriver
Adjustable
wrench
that opens to 1"
(2.5 cm) or hex-head
socket wrench
(for adjusting
dryer feet)
level
YX' nut driver
or socket wrench
Knife
Vent clamps
Pipe-joint
compound
resistant
to [.P gas
Caulking
gun and compound
(for
installing
new exhaust
vent)
Pliers
Parts supplied:
Remove parts package from dryer drum. Check that all parts were included.
A. Leveling legs (4)
C. Short inlet hose
D. Inlet hose with right-angle connector
E. Rubber washer
Parts needed:
Check
local codes and consult
gas supplier.
Check existing
gas supply, electrical
supply
and
venting,
and read "Electrical
Requirements,"
"Gas Supply
Requirements"
and "Venting
Requirements"
before purchasing
parts.
Mobile
home installations
require special
parts (listed following)
that may be ordered
by
calling
the dealer
from whom
you purchased
your dryer. For information
on ordering,
please
refer to the "Assistance
or Service"
section.
You may also contact
the dealer from whom
you
purchased
your dryer.
Mobile
home installation
kit. Ask for Part Number
346764.
Explosion
Hazard
Keep
flammable
materials
and vapors,
such
as
gasoline,
away
from
dryer.
Place
dryer at least
18 inches
(46 cm) above
the floor
for a garage
installation.
Failure
to do so can result
in death,
explosion,
or fire.
You will
need
A location
that allows
for proper exhaust
installation.
See "Venting
Requirements."
A separate
30-amp
circuit.
A grounded
electrical
outlet
located
within
2 ft (61 cm) of either side of the dryer. See
"Electrical
Requirements."
A sturdy floor to support
the total weight
(dryer and load) of 200 Ibs (90.7 kg). [he
combined
weight
of a companion
appliance
should
also be considered.
Cold water faucets
located
within
4 ft (1.2 m) of the water fill valves, and water pressure
of 20-100
psi (138-690
kPa). You may use the water supply
for your washer
using the "Y"
connector
and short hose (if needed) which
are provided.
20-100
psi (138-690
kPa) for best performance.
A level floor with
a maximum
slope of 1" (2.5 cm) under entire
dryer.
Do not operate
your dryer at temperatures
below
45°F (7°C). At lower temperatures,
the dryer
might not shut off at the end of an automatic
cycle. Drying
times can be extended.
[he dryer must not be installed
or stored in an area where it will
be exposed
to water and/or
weather.
Check code requirements.
Some codes limit,
or do not permit,
installation
of the dryer in
garages, closets,
mobile
homes or sleeping
quarters.
Contact
your local
building
inspector.
NOTE:
No other fuel-burning
appliance
can be installed
in the same closet as a dryer.
Metal exhaust
system hardware.
....
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bravos mgd6600tq1

Table of Contents