Operation°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°
Electmnfc
Central
Ranel
Tile pictured control panel is similar to your panel.
• Check Filter
Set Temperature/
Timer DisjJlay
_
Temperatur_VTimer
Hour Controls
--
Timer Control
Mode
Control
The Mode
Control
has three
settings:
Fan, Cool and
Energy
Saver.
A green
light will indicate
which
mode
is
currently
being utilized.
Cool
Mode
- The unit will circulate
and cool the air.
Fan Mode
- The unit will only circulate
the air.
Energy
Saver
Mode
- The fan will switch
from the set
fan speed
to LO whenever
the
compressor
turns
off in
response
to the thermostat.
When
the compressor
cycles
back on, the unit will return
to the original
fan setting.
Check Filter
Light/Reset
Fan Speed
Control
--
Mode
Control
Power Control
Fan
Speed
Control
The
Fan
Speed
Control
has four
settings:
High,
Medium,
Low and Auto. The settings
are adjusted
with the
Fan Speed
Control,
each time
the button
is depressed
it
changes
the setting.
A green light will indicate
which
set-
ting is currently
being used.
When
the Auto feature
is selected
while the air condition-
er is in the COOL mode,
the fan speeds
will change
auto-
matically
as the temperature
in the room changes.
• 7 ° or more above the set temperature
will use HI fan.
• 4 ° - 7 ° above the set temperature
will use IVIED fan.
• 4 ° or less above the set temperature
will use LO fan.
Timer
Control
The timer
can be set to either turn the unit on or off.
Power
Control
The Power Control
turns the unit on and off.
Set Temperature/Timer
Display
Shows
the set temperature
when
the unit is in operation
and
hours
when
the timer
is being
set. THE TEMPERA-
TURE DISPLAY ONLY SHOWS
THE SET TEMPERATURE,
NOT THE ACTUAL ROOM TEMPERATURE.
Temperature/Timer
Hour
Controls
These
buttons
are used to raise or lower
the set tempera-
ture
in increments
of 1 ° from
66 ° to 88 °. By depressing
both
buttons
at once,
the
display
will
toggle
between
Celsius
and Fahrenheit.
When
the timer is being set, these
buttons
are used to change
the hour setting
in increments
of 1 from 00 to 24.
Check
Filter
Light/Reset
After 250 hours
of usage the Check
Filter light will turn
on.
At this
time,
the
filter
needs
to be
removed
and
cleaned
(see page S). After the filter is cleaned
and reposi-
tioned,
depress
the
Reset
button.
This
will
restart
the
counter
and turn the light off.
To turn the unit ON using theTimer:
• Depress
the timer
key when
the power is off, the
display
will read 00. Adjust
to the desired
number
of
hours before
TURN ON using the up/down
arrows.
• The display
will show the time by hours
left
until TURN ON.
• To turn the timer
off, depress
the timer key.
• A green light next to the Timer Control
indicates
that
the timer
is set.
To turn the unit OFF using theTimer.
• Depress the timer key when the power is on, the display
will read 00. Adjust to the desired number
of hours
before TURN OFF using the up/down
arrows. The display
will automatically
go back to the set temperature
after 10
seconds.
• To display
the amount
of time
left until TURN OFF,
depress
the timer button
once.
• To turn the TIMER OFF, depress
the timer
button
twice.
• A green light next to the Timer
Control
indicates
that
the timer is set.
Built-in
three
minute
timing
delay.
This
electronic
controlled
unit
will
not
automatically
resume
operation
after a power
failure.
ff this
electric
unit
will
not
respond
to
touch
pad
or
remote
control
commands,
it is necessary
to unplug
the
unit from
the
electrical
outlet
for five seconds
and
then
plug the unit back in.plug
the unit back in
4