Controls and Installation, cont'd

Installation

Installation overview

Except where noted, the installation procedures for the various
interface models are the same. See "Cabling" in this chapter for
additional information.
If desired, mount the interface to an equipment rack
1
(RGB 164xi only) or to or through a desk or other suitable
surface using Extron's optional mounting kit. See
"Mounting the interface" in the next section.
2
Turn off power to the computer and its monitor. Turn off
power to the projector or display device. Disconnect the
power cord from the interface.
3
If a local computer monitor is being used, connect the
monitor to the Buffered Local Monitor Output connector.
4
For audio connections, see the "Cabling" section in this
chapter.
5
Connect the projector or other output display device(s) to
the interface's BNC output connectors, as described in the
"Cabling" section in this chapter.
6
Set the interface's DIP switches. See "Setting the DIP
switches" at the end of this chapter.
7
Power on the computer, monitor, projector/display device,
and the interface. The image should now display on
screen. If it does not, double check steps 2 through 7 and
make adjustments as needed. To adjust horizontal sync
polarity and to set vertical sync pulse width, see "Setting
internal jumpers" section at the end of this chapter.
RGB 160xi and RGB 164xi • Controls and Installation
2-4

Mounting the interface

The RGB 164xi can be mounted on a rack. Both the RGB 160xi
and the RGB 164xi can be mounted under or through a desk or
other surface using optional mounting kits.

Rack mounting (RGB 164xi only)

If desired, mount the RGB 164xi on an optional Extron
RSU 129 1U universal rack shelf kit (part #60-190-01) or
RSB 129 1U basic rack shelf (part #60-604-01) and in an
equipment rack (figure 2-5) as follows:
1U Universal Rack Shelf
1U Universal Rack Shelf
Front false
Front false
faceplate
faceplate
uses 2
uses 2
screws.
screws.
Use 2 mounting holes on
Use 2 mounting holes on
opposite corners.
opposite corners.
Figure 2-5 — Rack mounting the RGB 164xi
1.
Remove the feet from the bottom of the case if installed.
2.
Mount the converter on the rack shelf, using two
4-40 x 3/16" screws in opposite (diagonal) corners.
3.
Install a blank panel (not included with the basic rack
shelf) or another 1U half-rack unit on the unused side of
the rack.
RGB 160xi and 164xi • Controls and Installation
1/2 Rack Width Front False
1/2 Rack Width Front False
Faceplate
Faceplate
(2) 4-40 x 3/16"
(2) 4-40 x 3/16"
Screws
Screws
NOTE:
NOTE:
Using screws longer
Using screws longer
than 3/16" will damage the
than 3/16" will damage the
unit and void the warranty.
unit and void the warranty.
2-5