Reset Button; Power.connection - Extron electronics MVX Plus 128 VGA A User Manual

Computer video (vga) and audio matrix switcher
Table of Contents

Advertisement

Side
Clip Down
Pins
1&2
Figure 2-6 — RJ-45 connector and pinout tables

Reset button

g
Reset button — The Reset button initiates four levels of reset to the matrix
switcher. For two different reset levels, press and hold the button while
RESET
the switcher is running or while you power up the switcher.
See "Rear Panel Controls" in chapter 3, "Operation", for details.
• Events (mode 3) reset — Hold Reset for 3 seconds, then release it and push
it again to toggle events monitoring on and off.
• IP settings (mode 4) reset — Hold Reset for 6 seconds, then release it and
push it again to reset the switcher's IP functions.
N
The IP settings reset does not replace any user-installed firmware.
• Absolute (mode 5) reset — Hold Reset for 9, seconds then release it and
push it again to restore the switcher to the default factory conditions.
• Hard reset — Hold Reset while powering up the switcher to restore the
switcher to the default factory conditions.
N
Hard reset does not clear the current configuration.
Power connection
h
AC power connector — Plug a standard IEC power cord into this connector to
connect the switcher to a 100 VAC to 240 VAC, 50 or 60 Hz power source.
1
2 3 4 5 6 7 8
RJ-45
connector
1
2 3 4 5 6 7 8
Twisted
Pairs
7&8
3&6 4&5
MVX Plus 128 VGA A Matrix Switcher • Installation
Patch (straight) cable
Side 1
Pin
Wire color
Pin
1
White-orange
1
White-orange
2
Orange
2
Orange
3
White-green
3
White-green
4
Blue
4
Blue
5
White-blue
5
White-blue
6
Green
6
Green
7
White-brown
7
White-brown
8
Brown
8
Brown
Crossover cable
Side 1
Pin
Wire color
Pin
1
White-orange
1
White-green
2
Orange
2
Green
3
White-green
3
White-orange
4
Blue
4
Blue
5
White-blue
5
White-blue
6
Green
6
Orange
7
White-brown
7
White-brown
8
Brown
8
Brown
Side 2
Wire color
Side 2
Wire color