INSTALLATION
REQUIREMENTS
_?' i_: _ _._1:_
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
•
Level
•
Drill
•
Drill 1W' (3 cm) drill bit
•
3/32"(2.4 ram) drill bit if installing into wood
•
Pencil
•
Wire stripper or utility knife
•
Tape measure or ruler
•
Pliers
•
Caulking gun and weatherproof
caulking compound
•
Vent clamps
•
Jigsaw or keyhole saw
•
Flat-blade screwdriver
•
Metal snips
•
Phillips screwdriver
•
Scissors
Parts needed
•
Home power supply cable
•
1 - 1/2"(12.7 ram) UL listed or CSA approved strain relief
•
3 UL listed wire connectors
•
1 wall or roof cap
•
Metal vent system
•
2 - 175-watt max heat lamp bulbs
•
Blower motor system - internal or external (see "Blower
Motor System" in the "Accessories"
section.)
Parts supplied
Remove parts from packages. Check that all parts are included.
•
2 metal grease filters for 36" (91.4 cm) models
3 metal grease filters for 48" (121.9 cm) models
•
Damper
•
2 - Vent cover support brackets
•
2 - 10 x 50 mm mounting screws
•
2 - 8 x 40 mm mounting screws
•
2 - D5.3 x 20 mm washers
•
4-5x45mmscrews
•
6- 4.2 x 8 mm screws
•
T-20 TORX®t adapter
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility
to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating
plate is located inside the range hood on the rear wall of the
range hood.
Canopy range hood location should be away from strong draft
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions
provide minimum clearance.
The canopy range hood is factory set for venting through the roof
or through the wall.
All openings in ceiling and wall where canopy range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Vented Installations
[
2472" (62.3
cm)
rain.
327/16 '' (82.4
cm)
max.
77/8" (20.0 cm)
25"
(63,5
cm)
I"®TORX is a registered trademark
of Saturn Fasteners, Inc.