Install Range Hood Internal Blower Motor; Motor System - KitchenAid KXW9748YSS0 Installation Instructions And Use & Care Manual

36" (91.4 cm) and 48" (121.9 cm) designer commercial-style wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

4=
Install the 6 mm nuts to the outside top or outside back
(alternate location on some models) of the range hood at the
proper location for the selected motor system.
Two 6 mm nuts are required for the single motor system.
Clip nuts into the small square notches located at the left
and right end of the square vent opening.
Five 6 mm nuts are required for the dual motor system.
Clip nuts into the small square notches, one located in the
front of the square vent opening and the other four
located at the left and right ends of the square vent
opening.
A
B
A. Clip nut locations for dual motor assembly (5)
B. Clip nut locations for single motor assembly (2)
5. Mount range hood. See the "Install Range Hood" section.
Install Range Hood Internal Blower Motor
1=
Install the range hood blower motor assembly inside the
range hood canopy with the wiring connection to the left for
the single motor system and to the front or top for the dual
motor system.
Single Blower Motor Assembly
A. Wiring connection
Dual Blower Motor Assembly
A
A. Wiring connection
2. Slide the left mounting plate flange under the motor mounting
bracket.
3=
A. Motor mounting bracket
B. Mounting plate left flange
Run the power supply wires and connector from the range
hood through the hole in the right end of the motor mounting
plate.
A
,?,/'
B
A. Motor mounting plate hole
B. Power supply wires and connector

Hide quick links: