32" (81.3 cm) wall-mount perimetric range hood installation instructions
Table of Contents

Advertisement

Available languages

Available languages

This range h ood canbesetforrear v enting u sing the31¼" x 10"
(8.3 x25.4 cm)rectangular
damper (supplied).
1. Using 2ormore people, setrange h ood ontoitsback ona
covered s urface.
2. Push inthebottom ofthecenter glass t ounlatch, andliftto
open. Remove the2screws thathold ittothecanopy. Setthe
glass c over a ndthemounting screws a side.
6. Remove the4screws h olding t heblower motor t othecanopy
top.Push blower uptorelease themounting tabs from the
keyhole slots. R emove blower motor. Setblower motor a nd
mounting screws a side.
0
B
o
A
3,
4.
A. Remove these
screws.
Remove metal filter. See the "Range Hood Care" section.
Disconnect
the blower wiring plug.
A
A. Keyhole slot
B. Mounting tab
7. Remove the 4 screws from the cover plate on the back of the
canopy.
8. Install cover plate over the rectangular top exhaust hole using
its 4 mounting screws. Tighten screws.
B ..........................................
!l® ®
® I
5,
A. Blower wiring plug
B. Blower
Remove the 4 mounting screws holding the 8" (20.3 cm)
diameter transition damper to the canopy top. Set the
damper and mounting screws aside.
A
A. Remove cover plate from here.
B. Replace cover plate here.
A. Damper mounting screws