6. DRAINING
THE WATER
Draining
the
water
if the red light is lit, iodicatiog
that the ioteroal
bucket is full, follow the recommended
water draining
procedure:
D
Upper
Drain
Valve
1.
The unit must be switched
to the off position,
2,
Place a container
under
the upper
drain
valve and remove
the rubber
plug
from the
upper
drain
valve
(Fig. 7 a, b, c).
3,
Insert the drain
hose on the upper
drain
valve
pointing
it towards
the container,
4,
Turn the upper
drain
valve
from the closed
position
to the open
position
(Fig. 7 b).
5,
Turn the unit on, turn the thermostat
to the
warmest
setting
and the switch
to the dehu-
midify
position.
The unit will
turn on, allow-
ing the pump
to run and drain
the water
from the unit
(Fig. 6).
6,
When
the water
stops draining
from
the unit,
turn off the unit,
7,
Close the upper
drain
valve,
remove
the
drain
hose,
remove
the container
of water,
put the rubber
plug back
in the upper
drain
valve
(Fig. 7 d).
8,
Tile
unit can be turned
to any operating
nlode.
important:
When changing
the operating
mode back to
cooling
do not forget
to put the rubber
plug back in
and turn the upper drain valve 900 to the right or to
the closed
position.
If this is not done
the water
will
come
out of the unit when
it is switched
on,