Before You Call For Service - Kenmore Room Air Conditioners Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Before
You Call for
Before calling for service, review this list It may save you time and expense. This list
includes common occurrences
that are not the result of defective workmanship
or
Service...
materials in this appliance
OCCURRENCE
SOLUTION
Air conditioner will not operate,
Wal! plug disconnected
Push plug firmly into wall outlet
House fuse blown or circuit breaker tripped Replacefuse with time delay type or reset circuit breaker
FAN selector in OFF position
Turn FAN selector to the desired FAN setting
Unit turned off by moving TEMP Control to a warmer setting and then immediately turning back
to a colder setting Wait approximately 3 minutes Listen for compressor to start
Unit turned off and then on too quickly Turn unit off and wait 3 minutes before restarting
TEMPControl set warmer than room temperature Turn TEMP Control clockwise to a colder setting
(thick rule)
Air from unit does not feel cold
Turn selector to a higher FAN position
enough°
TEMP Control set too warm (thin rule) Turn TEMPControl clockwise to a colder setting (thick rule)
Room temperature below 70"F(21°C) Cooling may not eccu r until room temperature risesabove
70"F _2_°C).
Temperature sensing tube touching cold coil, located behind air filter Straighten tube away from coil
Air conditioner cooling, but room is
Outdoor temperature below 70"F (21°C) To defrost the coil, set selector to FAN position Then,
too warm
- - ice forming on cooling
turn TEMP Control clockwise to a warmer setting (thin rule)
coil behind decorative
front,
Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost, set selector
to FAN
TEMP CONTROL set too cold for night-time cooling To defrost the coil, set selector to a FAN
position
Then, set TEMP CONTROL to a warmer position
Air conditioner
cooling,
but room is
Dirty air filter--air restricted Clean air filter Refer to Care and Cleaning section
too
warm
*-
NO_ ice forming
on
cooling coil behind
decorative front,
TEMPControl set too warm
Turn TEMPControl clockwise to a colder setting (thick rule).
Vent set at OPEN position
Set vent at CLOSED position for maximum cooling
Air directional louvres positioned improperly
Position Iouvres for better air distribution
Front of unit is blocked by drapes, blinds, furniture, etc -- restricts air distribution
Clear blockage
in front of unit
Doors, windows, registers, etc open --cold air escapes Close doors, windows, registers, etc
Unit recently turned on in hot room Allow additional time to remove "stored heat" from walls,
ceiling, floor and furniture
Dirty air filter-- air restricted Clean air filter
Air
conditioner
turns
on and
off
Outside temperature extremely hot Set FAN on high speed to bring air past cooling coils more
rapidly
frequently
Noise when unit is cooling_
Air movement sound This is normal If too loud, turn selector to lower FAN setting
Sound of fan hitting water.moisture
removal system This is normal when humidity is high Close
doors, windows and registers
Window vibration--poor
installation
Refer to installation instructions or check with installer
Water
dripping INSIDE when unit is
Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer
cooling°
to installation instructions--check with installer,
Water dripping
OUTSIDE when unit
Unit removing large quantity of moisture from humid room
This is normal during excessively
is cooling,
humid days
9