Download Print this page

Before Calling For Service - Jenn-Air JIM1550ARW Owner's Manual

Hide thumbs Also See for JIM1550ARW:

Advertisement

Available languages

Available languages

41007621
JA
Ice Maker
ENG
4/28/03
2:18
PM
Page
18
+
Before Calling for Service, co.,
Inadequate
drain system.
Restriction
or improperly
installed drain lines
Water keeps backing
up into the ice bin
(gravity
drain).
Foreign material in ice bin drain.
Water
keeps
backing
Drain pump tubing
kinked or
up into the ice bin
restricted.
(drain
pump).
Inlet screen to the drain pump is
restricted
or blocked.
Drain pump and/or the ice machine
are not level.
The drain pump cycles
Vent line to the drain pump is
on and off erratically,
restricted
or kinked.
Discharge
line is restricted or
k in ked.
The drain pump is not level.
will cause water to back up into the ice bin.
Make certain there are no kinks or restrictions
in the drain lines. If necessary, consult a
qualified
plumber.
Foreign material is restricting
or blocking the
ice bin drain located at the right rear corner of
the ice bin. The drain will need to be cleared.
Check inlet, discharge,
and vent line tubing for
any kinks or restrictions
and repair as
necessary.
Clean the inlet screen to the drain pump.
Check and level is necessary the drain pump
as well as the ice machine.
Check the vent line for any restrictions
or
kinks and repair as necessary.
Check the discharge
line and connection
to
the desired drain for any restrictions
or kinks
and repair as necessary.
The drain pump must be level. Check for level
on the top of the drain pump case and adjust
the tubing
or use shims to level.
18
+

Advertisement

loading

This manual is also suitable for:

Jim1550arbJim1550acxJim1550ars