Spark Arrester - Honda Harmony FG100 Owner's Manual

Mini-tiller
Hide thumbs Also See for Harmony FG100:
Table of Contents

Advertisement

Spark
Attester
Service
The spark arrester
must be serviced
every 100
hours to keep it functioning
as designed.
tf the engine has been running,
the muffler
will be
very hot. Allow the muffler to cool before servicing
the spark arrester.
1. Remove
the four 5 x 18 mm bolts from the
recoil starter, and remove the recoil starter.
2.
Disconnect
the spark plug cap from the spark
plug. Pull the spark plug wire and the ignition
switch wire out of the retainers
in the top cover.
3.
Remove
the two 5 x 22 mm bolts from the top
cover, and remove the top cover.
4.
Remove
the three 5 mm screws from the
muffler cover,
and remove the muffler cover.
5.
Remove
the special screw from the exhaust
deflector,
and remove the exhaust
deflector.
6.
Remove
the special screw from the spark
arrester,
and remove the spark arrester.
7.
Use a brush to remove carbon
deposits
from
the spark arrester
screen.
Be careful to avoid
damaging
the screen.
The spark arrester
must be free of breaks and
holes. Replace the spark arrester
if it is
damaged.
8.
Install the spark arrester,
muffler cover, top
cover, and recoil starter
in the reverse order of
disassembly.
SPARK
ARRESTER
SCREEN
SPECIAL
SCREW
EXHAUST
DEFLECTOR
MAINTENANCE
& ADJUSTMENTS
RECOIL STARTER
/
BOLT, 5 x 18 mm (4)
iGNiTiON
SWITCH WiRE
SPARK
PLUG
CAP
RETAINERS
TOP
/
COVER
SPARK
ARRESTER
SCREW,
COVER
SPECIAL
SCREW
FG100 TILLER