How to replace
the brushes
Disconnect cleaner from electrical outlet.
replace worn brushes, remove bottom plate, belt and agitator, fol-
directions given on preceding pages.
END
SECTI 0 N
2. Turn end plates of agitator
in
opposite
directions
until one end
plate comes
off.
3. Then pry out end section as
shown.
4. Remove
opposite
end plate
and shaft by pulling straight
out.
Pry out remaining
end section.
6. To reassemble,
reverse
proce-
dure. Replace the last end sec-
tion removed,
then end plate and
shaft.
Replace
remaining
end sec-
tion and end plate. Be sure end
sections
are assembled
with Ioca-
tor lined up with slot in agitator.
5. Remove brushes by pulling them
from agitator. Use pliers if neces-
sary. Slide new brushes into chan-
nels. Push them in as far as possi-
ble.
END SECTION
7. Should you accidentally dis-
place the bearing during disas-
sembly, reassemble as shown.