Savetime and money! Reviewthe chart below first
and _touma_tnot needto call for service.
Possible Causes
What To Do
Fan/Light does not
operate when either
button is pressed
Fan does not operate
when fan + or- buttons
or MEMORY/OFF button
is pressed
Loud or abnormal
airflow noise
A house
fuse
may be blown
or a circuit
breaker
tripped.
The blower connector
is loose
or not plugged into its mating
connector.
Wrong duct size used in
installation.
• Replace fuse or reset circuit breaker.
• Disconnect power to the unit. Remove the filters
and look up at the blower. If the blower connector
plug is loose or gou see the connector dangling,
the installer failed to plug it in securelg. See the
Installation Instructions for the plug location and how
to plug in the connector.
oThis hood requires 8" ducting and a maximum duct
length of !00 equivalent feet to perform optimallg.
Using smaller duct pipe or longer equivalent lengths
of duct pipe will cause improper venting. GE service
technicians cannot correct this issue if installed
improperlg.
Fan fails to circulate air
Obstructions
in duct work.
• Hake sure nothing is blocking the vent. Hake sure
ormoves airslower
gour wall or roof cap has a blade or door.
than normal and/or fan
Damper blade on wall or roof
• Hake sure damper swings freely. Damper blades may
is making loud or
cap meg not be open.
flip over and will not fully open when this happens.
abnormal
airflow noise
Adjust to original position.
Metal grease filter and charcoal
oClean the metal grease filter and replace charcoal
filter (if present} meg be dirtg,
filter (if present). See Care and Cleaning of the Vent
Hood.
The hood controls are
Control logic confused.
• Disconnect power to the hood bg resetting the circuit
not operating
correctly
breaker. Wait ]0 seconds to allow controls to reset.
Early bulb failure
Replacing bulbs with bare hands. * Replace bulbs while wearing gloves to keep skin oils
off bulbs.
• Bulb wattage is too high. Replace with correct
wattage.
The memorg feature of this
hood has not been set. This is
normal.
Hood does not appear
to operate when the
MEMORY/OFF button
is pressed. All collars
around the push buttons
are illuminated.
• Follow procedures for setting the MEMORY/OFF
button. Adjust the Fan and Light settings to your
preference.