GE Profile PV976 Owner's Manual And Installation Instructions page 16

Chimney vent hoods
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
INSTALLATION--VENTED TO THE OUTSIDE
I-_ CONNECT DUCTWORK
• Remove shipping tape from the damper.
• Install ductwork,
making connections
in the direction of airflow as illustrated.
• Push duct over the exhaust outlet and damper.
• Secure joints in ductwork
with sheet metal screws.
• Wrap all duct joints and the flange connections
with aluminized
duct tape for an airtight
seal.
Airflow
Duct tape
_
over seam
___
Screw
and screw
_
]
-&CAUTION:
Do mot use sheet metal
screws at the hood flangeconnection. Doing so will
preventproper damper operation. Sealconnection
withtape only.
CONNECT ELECTRICAL
Verify that power
is turned
off at the source.
-&WAR N ING:lfhouse
wiring
isnot 2 -wire
with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum,
be sure to use U.L. approved anti-oxidant
compound
and aluminum-to-copper
connectors.
• Remove the 6 screws on the junction
box cover
and the knockout on the top left side.
Knockout
Juncti°n a"
_
iJ\
::X
box cover --___ _
I\ !\
• Secure the house wiring to the junction
box with
a strain relief (not provided).
• Connect the white lead to the branch circuit white lead.
• Connect the black lead to the branch circuit black lead.
Connect the green/yellow
lead to the branch
circuit green lead or bare ground lead.
Secure all the connections
with wire nuts on each
electrical connector.
Push the wires into the junction
box and replace
the cover. Be sure the wires are not pinched.
Secure the junction
box cover with the 6 original
screws.