Complete Chimney Support Installation; Make Electrical Connection; Install Chimney Covers - KitchenAid KICU460WSS0 Installation & Use Manual

36" (91.4 cm), 42" (106.7 cm) and 48" (121.9 cm) designer commercial-style island-mount canopy hood
Hide thumbs Also See for KICU460WSS0:
Table of Contents

Advertisement

Available languages

Available languages

Complete Chimney Support Installation

1. Remove wiring box cover located on the top section of the
chimney support.
2. Install a UL or CSA listed strain relief in the wiring box so that
the screws can be tightened after the chimney support is
attached to the ceiling.
3. Lift chimney support into its final location, feeding electrical
wire through the strain relief.
4. Position the chimney support so that the large end of the
keyhole slots are over the ceiling attachment bolts. Then
push the chimney support so that the bolts are in the neck of
the slots. Tighten bolts securely.
IMPORTANT: The chimney support must be securely
attached to the ceiling.
5. Determine the desired length of the chimney support.
6. Remove the four screws and adjust the length of the lower
chimney support as needed.
NOTE: This is the only section that can be adjusted.
7. Replace the four screws and tighten securely.

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved
4. Run 3 wires, black, white and green, in
service panel to terminal box. Use caulking to seal openings.
8
A
A. Screws
" strain relief.
" conduit from
5. Attach terminal box to the wall and securely tighten screws.
A
B
C
D
A. Home power supply cable
B. Black wires
C. UL listed wire connectors
D. White wires
E. Green (or bare) ground wire from home power
supply connected to green ground screw
F. Range hood power supply cable
G. Range hood power supply cable connected to
green ground screw
6. Use UL listed wire connectors and connect black wires (B)
together.
7. Use UL listed wire connectors and connect white wires (D)
together.
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
8. Connect green (or bare) ground wire from home power supply
to the unused green ground screw (E) in the terminal box.
9. Tighten strain relief screws.
10. Install terminal box cover.
11. Check all light bulbs to make sure they are secure in their
sockets.
12. Reconnect power.

Install Chimney Covers

Chimney Cover Installation
1. Attach the vent system to the damper. Seal all joints with vent
clamp.
2. Remove the plastic covering from the chimney covers.
E
G
F

Advertisement

Table of Contents
loading

Table of Contents