PRODUCT MODEL NUMBERS
KICU465S
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit is
recommended.
VENTING REQUIREMENTS
Vertical roof venting
Horizontal wall venting
roof cap
To calculate the length of the system
you need, add the equivalent feet
(meters) for each vent piece used in
the system.
Vent piece
8" (20.3 cm) round
45° elbow
2.5 feet
(0.8 m)
90° elbow
5.0 feet
(1.5 m)
6" (15.2 cm) vent system
90° elbow
6 ft. (1.8 m)
Maximum length
2 ft.
(0.6 m)
1 — 90° elbow
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
1 — wall cap
system length
Note: Flexible vent is Not recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®
36" Island Range Hood
OVERALL DIMENSIONS
3
"
(10.0 cm)
27 "
(69.9 cm)
wall
cap
CABINET OPENING DIMENSIONS
wall
cap
36" (91.4 cm)
Countertop
height
= 35 ft. (10.7 m)
= 5 ft. (1.5 m)
= 0 ft. (0 m)
=13 ft. (3.9 m)
Vented chimney dimensions
12
"
13 "
(30.6 cm)
(34.9 cm)
23 "
(60.0 cm)
36" (91.4 cm)
X
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Non-vented (recirculating)
chimney dimensions
13 "
(34.9 cm)
26 "
(65.1 cm)
min.
38 "
(97.8 cm)
3 "
max.
(8.9 cm)
12 "
5"
(31.8 cm)
(12.7 cm)
Note: The hood chimneys are adjustable
and designed to meet varying ceiling or
soffit heights depending on the distance
"X" between the bottom of the hood and
the cooking surface. For higher ceilings, a
40" (101.6 cm) Chimney Extension Kit Part
Number 8212698 (Black), Kit Part Number
8212696 (Stainless Steel) or Kit Part Number
8212697 (White) is available. See your
dealer. The chimney extension replaces the
upper chimney shipped with the hood.
Important:
Minimum distance "X": 24" (61.0 cm)
Suggested maximum distance "X":
See NOTE
30" (76.2 cm)
For vented installations, the chimney can be
adjusted for ceilings between 7' 7-1/8"
(2.31 m) and 9' 1-3/4" (2.79 m).
For non-vented (recirculating) installations,
the chimney can be adjusted for ceilings
between 8' 3-3/8" (2.52 m) and 9' 5-1/4"
(2.88 m).