1. Remove wiring box cover located on the top section of the
chimney support.
2. Install a UL or CSA listed strain relief in the wiring box so that
the screws can be tightened after the chimney support is
attached to the ceiling.
3. Lift chimney support into its final location, feeding electrical
wire through the strain relief.
4. Position the chimney support so that the large end of the
keyhole slots are over the ceiling attachment
bolts. Then
push the chimney support so that the bolts are in the neck of
the slots. Tighten bolts securely.
IMPORTANT: The chimney support must be securely
attached to the ceiling.
5. Determine the desired length of the chimney support.
6. Remove the four screws and adjust the length of the lower
chimney support as needed.
NOTE: This is the only section that can be adjusted.
7=
A. Screws
Replace the four screws and tighten securely.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved V2"strain relief.
4. Run 3 wires, black, white and green, in V2"conduit from
service panel to terminal box. Use caulking to seal openings.
5. Attach terminal box to the wall and securely tighten screws.
C
D
A. Home power supply cable
B. Black wires
C. UL listed wire connectors
D. White wires
E. Green (or bare) ground wire from home power
supply connected
to green ground screw
F. Range hood power supply cable
G. Range hood power supply cable connected
to
green ground screw
6. Use UL listed wire connectors
and connect black wires (B)
together.
7. Use UL listed wire connectors
and connect white wires (D)
together.
Fire Hazard
Electrically ground the blower.
Use copper
wire.
Connect
ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical
shock.
8. Connect green (or bare) ground wire from home power supply
to the unused green ground screw (E) in the terminal box.
9. Tighten strain relief screws.
10. Install terminal box cover.
11. Check all light bulbs to make sure they are secure in their
sockets.
12. Reconnect power.
I".....
I I =
I ........
II?:SI)ilII ( l]ll]'llS(
/()V_::_I_!;i)
Chimney Cover Installation
1. Attach the vent system to the damper. Seal all joints with vent
clamp.
2. Remove the plastic covering from the chimney covers.