Campbell CS105 Instruction Manual

Barometric pressure sensor

Advertisement

Quick Links

CS105/CS105MD
Barometric Pressure Sensor
Revision: 3/07
C o p y r i g h t
©
1 9 9 5 - 2 0 0 7
C a m p b e l l
S c i e n t i f i c ,
I n c .

Advertisement

Table of Contents
loading

Summary of Contents for Campbell CS105

  • Page 1 CS105/CS105MD Barometric Pressure Sensor Revision: 3/07 C o p y r i g h t © 1 9 9 5 - 2 0 0 7 C a m p b e l l S c i e n t i f i c , I n c .
  • Page 2 Warranty and Assistance The CS105/CS105MD BAROMETRIC PRESSURE SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty.
  • Page 3: Table Of Contents

    CS105/CS105MD Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. General .................1 2. Specifications ..............1 3. Installation and Wiring ..........2 4.
  • Page 4 This is a blank page.
  • Page 5: General

    CS105/CS105MD Barometric Pressure Sensor 1. General The CS105 analog barometer uses Vaisala’s Barocap® silicon capacitive pressure sensor. The Barocap sensor has been designed for accurate and stable measurement of barometric pressure. The CS105 outputs a linear 0 to 2.5 VDC signal that corresponds to 600 to 1060 mb. It can be operated in a powerup or continuous mode.
  • Page 6: Installation And Wiring

    5 VDC. When the jumper is installed the CS105 is powered continuously. NOTE CS105s shipped from Campbell Scientific are configured for powerup mode (jumper open). NOTE CS105MDs shipped from Campbell Scientific are configured for continuous power mode (jumper closed).
  • Page 7: Cs105 Mounted On The Backplate Of An Enc12/14 Enclosure

    CS105/CS105MD Barometric Pressure Sensor FIGURE 1. CS105 Mounted on the Backplate of an ENC12/14 Enclosure, and Connected to a CR1000 Datalogger Logan, Utah INTERNAL BATTERY BPALK 12V ALKALINE BATTERY PACK TEMPARARY BATTER MADE IN USA PRESSURE TRANSMITTER MODEL PTB100A SERIAL NO P4450003 RANGE 800-1060 hPa...
  • Page 8: Cs105 Wiring Diagram

    CS105/CS105MD Barometric Pressure Sensor PRESSURE TRANSMITTER MODEL PTB101B SERIAL NO P4450003 RANGE 600-1060 hPa OUTPUT 0-2.5 VDC SUPPLY 10-30 VDC VAISALA MADE IN FINLAND See Table 1 Blue - Pressure (VOUT) See Table 1 Yellow - Signal Ground (AGND) Continuous 12 VDC Red - 12 VDC (SUPPLY) See Table 1 Black - Power Ground (GND) Control Port or Excitation Channel Green - Control (EXT.
  • Page 9: Cs105Md Wiring Diagram

    CS105/CS105MD Barometric Pressure Sensor PRESSURE TRANSMITTER MODEL PTB101B SERIAL NO P4450003 RANGE 600-1060 hPa OUTPUT 0-2.5 VDC SUPPLY 10-30 VDC VAISALA MADE IN FINLAND 6H Green - Pressure (VOUT) 6L White - Signal Ground (AGND) 12 V Switch Red - 12 VDC (SUPPLY) GND Black - Power Ground (GND) FIGURE 4.
  • Page 10: Programming

    4. Programming 4.1 CS105MD Programming the MetData1 station for the CS105MD is done through Campbell Scientific’s Short Cut program. Short Cut includes code in the .DLD file to correct for elevation. 4.2 CS105 Atmospheric pressure changes little with time. In most weather station applications measuring pressure once an hour is adequate.
  • Page 11 CS105/CS105MD Barometric Pressure Sensor Example 1. CR1000 Program for Measuring the CS105 Once Every Hour 'Main Program BeginProg Scan(5,Sec,1,0) 'CS105 Barometric Pressure Sensor measurement BP_mmHg: If IfTime(59,60,Min) Then PortSet(1,1) If IfTime(0,60,Min) Then VoltSE(BP_mmHg,1,mV2500,1,1,0,_50Hz,0.184,600.0) BP_mmHg=BP_mmHg*0.75006 PortSet(1,0) EndIf 'Call Data Tables and Store Data NextScan EndProg Example 2.
  • Page 12 CS105/CS105MD Barometric Pressure Sensor 07: Real Time (P77) 1: 0110 Day,Hour/Minute 08: Sample (P70) 1: 1 Reps 2: 1* Loc [ P_mb -Input Locations- 1 P_mb Proper entries will vary with program and datalogger channel, and input location assignments. ** On the 21X use the 5000 mV slow range. Example 3.
  • Page 13: Long Lead Lengths

    CS105/CS105MD Barometric Pressure Sensor -Input Locations- 1 P_mb Proper entries will vary with program and datalogger channel, and input location assignments. ** On the 21X use the 5000 mV slow range. Example 4. 21X Program for Measuring the CS105 Every Execution Interval Using an Excitation Channel to Turn the CS105 On and Off.
  • Page 14: Cs105

    CS105/CS105MD Barometric Pressure Sensor Example 5. CR10(X) Program for Measuring the CS105 Once Every Hour with Instruction 2 (Differential Measurement) ;{CR10X} *Table 1 Program 01: 10 Execution Interval (seconds) 01: If time is (P92) 1: 59 Minutes (Seconds --) into a 2: 60 Interval (same units as above) 3: 41*...
  • Page 15: Correcting Pressure To Sea Level

    Sea level correction is automatically coded into datalogger programs when using Short Cut. 7. Maintenance There are no user-serviceable parts on CS105. Vaisala recommends recalibrating the CS105 every year. Contact Campbell Scientific, Inc., phone (435) 753-2342, for an RMA number before returning the sensor for recalibration.
  • Page 16 CS105/CS105MD Barometric Pressure Sensor This is a blank page.
  • Page 17: Daily Average

    Appendix A. Daily Average If the CS105 will be measured every minute or faster, and a daily average is required, follow Example 5. In Example 5 the daily average, maximum, and minimum pressure is recorded at midnight. A constant is subtracted from the pressure before the average instruction is executed.
  • Page 18 Appendix A. Daily Average 08: Average (P71) 1: 1 Reps 2: 2* Loc [ P_const ] 09: If Flag/Port (P91) 1: 10 Do if Output Flag is High (Flag 0) 2: 30 Then Do 10: Z=X+F (P34) 1: 3* X Loc [ P_mb_avg ] 2: 800 3: 3* Z Loc [ P_mb_avg ]...
  • Page 19 This is a blank page.
  • Page 20 Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)