ADJUSTINGTHEMITERGAGE
See
Figure
521
The miter gage is used in making cross cuts in the
workpiece. To use the miter gage at an angle other
than 0", loosen both lock knobs and pull out the stop
pin. Move the miter gage rod to the desired angle.
_I= WARNING:
Make sure the switch is off, the
switch key is removed and the plug is not in the
outlet. Omission of these steps could allow
accidental starting, resulting in serious injury.
To check for alignment, set the miter gage at 0 ° and
plus or minus 45" by pulling the miter gage stop
pin. Adjust the stop screws, if needed.
Note: The miter gage provides close accuracy in
angled cuts. For very close tolerances, test cuts
are recommended.
Loosen the lock nut of the 0° stop screw at the stop
pin with an 8 mm wrench.
Place a 90 ° square against the miter gage rod and
the miter gage base.
If the rod is not square, loosen both lock knobs on
the top of the miter gage, adjust the rod, and
tighten the lock knobs.
Adjust the 0 ° stop screw until it rests against the
stop pin. Adjust the plus and minus 45" stop screws
using a 45" triangle and the steps above.
Push the quick release to quickly move the hold
down clamp onto the wood you are about to cut. To
prevent the use of the quick release roll the quick
release stop around to the top of the quick release.
This prevents the hold down clamp from dropping
on your workpiece:
REMOVING
/ REPLACING
THE THROAT
PLATE
See Figure 531
_i,
WARNING:
Make sure the switch is off, the
switch key is removed, and the plug is out of the
outlet. Accidental starting could cause serious
injury.
Loosen the screw in the throat plate with a phillips
screwdriver and lift the front end. Pull it out toward
the front of the saw.
To re-install the throat plate, place it in the opening.
Push it toward the rear of the saw base to engage
the spring clip.
Note: The keyslot in the throat plate will drop over the
screw.
QUICKRELEASE
QUICK RELEASE
STOP
DOWNCLAMP
LOCK KNOBS
MITERGAGE
KNOB
MITERGAGEROD
MITERGAGEBASE
STOP PIN
LOCKNUT
45° STOPSCREW
Fig. 52
Check that the throat plate is even with the table
top. If not, adjust the four comer setscrews with a
2 mm hex key. See the procedure in the Assembly
section.
Tighten the throat plate screw. Do not allow the
throat plate to bow up above the table surface.
THROATPLATE
SPRINGCLIP
KEYSLOT
SETSCREW (4)
/
/
TABLETOP
SCREW
Fig. 53