Example of RAID Manager commands with HOSTA:
Designate a group name (Oradb) and a local host P- VOL a case.
# paircreate
This command creates pairs for all LUs assigned to group Oradb in the configuration definition
file (two pairs for the configuration in above figure).
Designate a volume name (oradev1) and a local host P-VOL a case.
# paircreate
This command creates pairs for all LUs designated as oradev1 in the configuration definition file
(CL1-A,T1,L1 and CL1-D,T2,L1 for the configuration in above figure).
Designate a group name and display pair status.
# pairdisplay
Group
PairVol(L/R) (P,T#,L#),
oradb
oradev1(L)
oradb
oradev1(R)
oradb
oradev2(L)
oradb
oradev2(R)
Example of RAID Manager commands with HOSTB:
Designate a group name and a remote host P-VOL a case.
# paircreate
This command creates pairs for all LU designated as Oradb in the configuration definition file (two
pairs for the configuration in figure above).
Designate a volume name (oradev1) and a remote host P-VOL a case.
# paircreate
This command creates pairs for all LUs designated as oradev1 in the configuration definition file
(CL1-A,T1,L1 and CL1-D,T2,L1 for the configuration in above figure).
Designate a group name and display pair status.
# pairdisplay
Group
PairVol(L/R)
oradb
oradev1(L)
oradb
oradev1(R)
oradb
oradev2(L)
oradb
oradev2(R)
The command device is defined using the system raw device name (character-type device file
name). The command device defined in the configuration definition file must be established in a
way to be following either every instance. If one command device is used between different
instances on the same SCSI port, then the number of instances is up to 16 per command device.
If this restriction is exceeded, then use a different SCSI path for each instance. For example, the
command devices for the following figure would be:
HP-UX:
HORCM_CMD of HORCMINST0 = /dev/rdsk/c0t0d1 HORCM_CMD of HORCMINST1 =
/dev/rdsk/c1t0d1
Solaris:
HORCM_CMD of HORCMINST0 = /dev/rdsk/c0t0d1s2 HORCM_CMD of HORCMINST1 =
/dev/rdsk/c1t0d1s2
-g Oradb
-f
never
-g Oradb
-d oradev1
-g Oradb
Seq#,
LDEV#..P/S,
(CL1-A, 1,1) 30053
18..
(CL1-D, 2,1) 30053
19..
(CL1-A, 1,2) 30053
20..
(CL1-D, 2,2) 30053
21..
-g Oradb
-f
never
-g Oradb
-d
oradev1
-g
Oradb
(P,T#,L#), Seq#,LDEV#..P/S,
(CL1-D, 2,1) 30053
(CL1-A, 1,1) 30053
(CL1-D, 2,2) 30053
(CL1-A, 1,2) 30053
-vl
-f
never
-vl
Status, Fence, Seq#, P-LDEV# M
P-VOL
COPY
NEVER, 30053
S-VOL
COPY
NEVER, -----
P-VOL
COPY
NEVER, 30053
S-VOL
COPY
NEVER, -----
-vr
-f
never
-vr
Status, Fence,Seq#,P-LDEV# M
19.. S-VOL COPY
18.. P-VOL COPY
21.. S-VOL COPY
20.. P-VOL COPY
Examples of RAID Manager configurations
19
-
18
-
21
-
20
-
NEVER ,-----
18
NEVER ,30053
19
NEVER ,-----
20
NEVER ,30053
21
-
-
-
-
69