HP XP P9500 Configuration Manual page 57

Storageworks raid manager
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Example 9 Configuration file example – UNIX-based servers
HORCM_MON
#ip_address
service
HST1
horcm
HORCM_CMD
#unitID 0... (seq#30014)
#dev_name dev_name
/dev/rdsk/c0t0d0
#unitID 1... (seq#30015)
#dev_name dev_name
/dev/rdsk/c1t0d0
HORCM_DEV
#dev_group
dev_name
oradb
oradb1
oradb
oradb2
oralog
oralog1
oralog
oralog2
oralog
oralog3
oralog
oralog4
HORCM_INST
#dev_group
ip_address
oradb
HST2
oradb
HST3
oralog
HST3
Figure 12 Configuration file example – Windows servers
The configuration file sets the following parameters:
(1) HORCM_MON
The monitor parameter (HORCM_MON) defines the following values:
Ip_address: The network address (IPv4 or IPv6) of the local host. When HORCM has two or
more network addresses on different subnets or MPE/iX, enter NONE for IPv4 or NONE6 for
IPv6 here.
Service: Specifies the UDP port name assigned to the HORCM communication path, which is
registered in "/etc/services" ("\WINNT\system32\drivers\etc\services" in Windows,
"SYS$SYSROOT:[000000.TCPIP$ETC]SERVICES.DAT" in OpenVMS). If a port number is
specified instead of a port name, the port number is used.
poll(10ms)
timeout(10ms)
1000
3000
dev_name
dev_name
port#
TargetID
CL1-A
3
CL1-A
3
CL1-A
5
CL1-A1
5
CL1-A1
5
CL1-A1
5
service
horcm
horcm
horcm
LU#
MU#
1
0
1
1
0
0
1
1
h1
Sample configuration definition files
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9000 raid manager

Table of Contents