A Fibre-to-SCSI address conversion

Disks connected with Fibre Channel display as SCSI disks on UNIX hosts. Disks connected with
Fibre Channel connections can be fully utilized. RAID Manager converts Fibre Channel physical
addresses to SCSI target IDs (TIDs) using a conversion table (see
Table 14 (page 51)

Fibre-to-SCSI address conversion

Figure 9 Sample Fibre address conversion
Table 14 Limits for target IDs and LUNs
-
Port
Fibre
SCSI
Conversion table for Windows. The conversion table for Windows is based on conversion by an
Emulex driver. If the Fibre Channel adapter is different (for example, QLogic, HP), the target ID
that is indicated by the raidscan command may be different from the target ID on the Windows
host.
Example 6 "Using Raidscan to display TID and LUN for Fibre Channel devices"
of using the raidscan command to display the TID and LUN of Harddisk6 (HP driver). You must
start HORCM without the descriptions of HORCM_DEV or HORCM_INST in the configuration
definition file because of the unknown TIDs and LUNs.
shows the current limits for SCSI TIDs and LUNs on various operating systems.
HP-UX, other systems
TID
LUN
0 to 15
0 to 1023
0 to 15
0 to 7
Figure 9 (page
Solaris, IRIX systems
TID
LUN
0 to 125
0 to 1023
0 to 15
0 to 7
Fibre-to-SCSI address conversion
51)).
Windows systems
TID
LUN
0 to 31
0 to 1023
0 to 15
0 to 7
shows an example