Miscellaneous Troubleshooting; Suspension Among Journals - HP XP P9500 User Manual

Hp p9000 continuous access journal user guide (av400-96399, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 20 SIM reference codes, types, and descriptions (continued)
Reference code
Byte 22
Byte 23
DC
9X
DC
AX
Notes:
If the DKC emulation type is 2105 or 2107, the setting of the system option mode 308 determines whether the SIM
is reported to the host, as explained below:
When system option mode 308 is set to ON, the SIM is reported to the host.
When system option mode 308 is set to OFF, the SIM is not reported to the host. By default, system option mode
308 is set to OFF.

Miscellaneous troubleshooting

Suspension among journals

All the journals in a consistency group can be suspended when an error occurs in one journal.
This takes place under the following conditions:
The Continuous Access Journal system consists of multiple primary and secondary systems
The status of the failed journal is PJSE or PJSF.
At least one journal in the consistency group is in normal status.
The communications line between the RAID Manager and all primary systems are normal.
The following is provided for your information when the circumstances above are present:
When an error occurs, the status of the journal changes from normal to PJSE (suspended by
error).
For an error caused by overflowing capacity, status changes to PJSF.
When one journal becomes PJSE or PJSF, all other normal journals in PJNN status also become
PJSE status.
If you use RAID Manager and if a journal is in the normal status, it will be shown as PJNN.
Note that if some pairs in the journal become suspended by error but the whole journal does not
become suspended, the status of other journals will not change
Severity
Description
A failure has been detected in the
secondary system.
Serious
A volume being used by P-VOL of the Cnt
Ac-J Z pair for delta resync operation has
been suspended.
A failure has been detected in the primary
storage system.
Serious
A volume used in a P-VOL that is
configured in a multiple primary and
secondary system combination has been
suspended.
A failure has been detected in other
primary and secondary systems.
System generating the
SVP log
SIM
file
Yes, repeatedly.
Primary
storage
system
Primary storage
SIM Log
system
Miscellaneous troubleshooting
121

Advertisement

Table of Contents
loading

This manual is also suitable for:

Continuous access journal

Table of Contents