HP XP P9500 User Manual page 105

Hp p9000 continuous access journal user guide (av400-96399, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 16 Logical path troubleshooting (continued)
Path status
Description
Port number
The specified port number
invalid
is invalid. The cable is not
connected to the specified
port.
Communication
A timeout error has
error
occurred in the path
between the primary and
secondary systems.
Pair-Port Number
The specified port in the
Mismatch
secondary system is
physically disconnected
from the primary system.
Pair-Port Type
The specified port in the
Mismatch
secondary system is not
configured as an RCU
Target port.
Communication
The primary system is
Failed
connected to the secondary
system successfully, but
logical communication
timeout occurred.
In Progress
The processing of the
attribute modifying is in
progress.
Port Number
The specified port number
Mismatch
is not correct, or the cable
is not connected to the
specified port.
Logical Blockade
A failure occurs at a
primary system port.
A failure occurs at a
secondary system port.
A failure occurs in the path
relay equipment.
The connection cable is
physically broken.
Program Error
Program error is detected.
<blank>
This path was not
established.
Corrective action
Delete the failed path. Check the specified port number or the cable
connection and then retry.
Delete the failed path and retry.
Make sure of the following:
That you specified the correct secondary system port. Correct the
port number if necessary.
The primary and the secondary systems ports are connected with
cables. If the systems are not connected by cables, connect them
and retry the operation.
That the topology settings of ports on the primary and secondary
systems are correct.
Make sure that the specified port in the secondary system is configured
as an RCU target port.
Make sure that the secondary system port and network relay devices
(for example, cables and switches) are properly configured and
functioning.
Wait until the processing terminating.
Delete the error path.
Check the specified port number or cable connections, and then retry
the operation.
Repair the port status on the primary system.
Repair the port status on the secondary system. After that, delete the
path then add the path and the secondary system back again.
Repair the path relay equipment. After that, delete the path then add
the path and the secondary system back.
Replace the broken cable. After that, delete the path by using the
Delete Path or Delete DKC command, and then add the path and the
secondary system again by using the Add Path or Add DKC command.
Delete the path by using the Delete Path or Delete DKC command,
and then add the path and the secondary system again by using the
Add Path or Add DKC command.
Delete the failed path. You may need to change the minimum paths
setting or delete the secondary system in order to delete the path.
After deletion finishes, add the path and the secondary system by
using the Add Path or Add DKC command.
Troubleshooting logical paths 105