Upgrading Hard Drive Capacity - HP StorageWorks D2D100 - Backup System User Manual

Smart array p400 controller user guide
Hide thumbs Also See for StorageWorks D2D100 - Backup System:
Table of Contents

Advertisement

Back up as much data as possible from the logical drive.
1.
CAUTION: Do not remove the drive that has the media error. Doing so causes the logical drive to fail.
Restore data from backup. Writing data to the location of the unreadable sector often eliminates the
2.
error.
Remove and reinsert the replacement drive. This action restarts the rebuild process.
3.
If the rebuild process still terminates abnormally:
Delete and recreate the logical drive.
1.
Restore data from backup.
2.
Case 2: The replacement drive has failed.
Verify that the replacement drive is of the correct capacity and is a supported model. If these factors are
not the cause of the problem, use a different drive as the replacement.
Case 3: Another drive in the array has failed.
A drive that has recently failed can sometimes be made temporarily operational again by cycling the
server power.
Power down the server.
1.
Remove the replacement physical drive (the one undergoing a rebuild), and reinstall the drive that it
2.
is replacing.
Power up the server.
3.
If the newly failed drive seems to be operational again:
Back up any unsaved data.
1.
Remove the drive that was originally to be replaced, and reinsert the replacement physical drive. The
2.
rebuild process automatically restarts.
When the rebuild process has finished, replace the newly failed drive.
3.
However, if the newly failed drive has not recovered:
Remove the drive that was originally to be replaced, and reinsert the replacement physical drive.
1.
Replace the newly failed drive.
2.
Restore data from backup.
3.

Upgrading hard drive capacity

You can increase the storage capacity on a system even if there are no available drive bays by swapping
drives one at a time for higher capacity drives. This method is viable as long as a fault-tolerance method
is running.
CAUTION: Because it can take up to 15 minutes per gigabyte to rebuild the data in the new configuration,
the system is unprotected against drive failure for many hours while a given drive is upgraded. Perform drive
capacity upgrades only during periods of minimal system activity.
To upgrade hard drive capacity:
Back up all data.
1.
Replace any drive. The data on the new drive is re-created from redundant information on the
2.
remaining drives.
CAUTION: Do not replace any other drive until data rebuild on this drive is complete.
When data rebuild on the new drive is complete, the Online/Activity LED stops flashing steadily and
either flashes irregularly or glows steadily.
Replacing, moving, or adding hard drives 29