Hard Drive Blank - HP StorageWorks 500 Generation 2 Maintenance And Service Manual

Table of Contents

Advertisement

10
HP MSA 500 G2 Storage System Maintenance and Service Guide
1. Power down any attached servers. Refer to the server documentation.
2. Press the Power On/Standby button on the storage system. Wait for the
3. Disconnect the power cords.
The system is now without power.

Hard Drive Blank

To remove the component:
CAUTION: In systems that use external data storage, be sure
that the server is the first unit to be powered down and the last to be
powered back up. Taking this precaution ensures that the system does
not erroneously mark the drives as failed when the server is powered
up.
IMPORTANT: If installing a hot-plug device, it is not necessary to
power down the storage system.
system power LED to go from green to off.
CAUTION: To prevent improper cooling and thermal damage,
do not operate the storage system unless all bays are populated with
either a component or a blank.