Wegener UNITY 4600 User Manual page 51

Professional media receiver
Hide thumbs Also See for UNITY 4600:
Table of Contents

Advertisement

Table 3.3: Command Directory for U4600 Terminal Commands
SET parameter value
SET TO destination [time]
SET FROM source
parameter:
One of format, feed, freq [for "carrier freq"], rate [for "data rate"], FEC, tag [for "tag site"],
prog [for "program"], margin [for "Eb/No margin warning zone"], aud1, or aud2 [for
"descriptors assigned to audio ports 1 and 2"]. See
definitions and limits.
value:
Value of the parameter as in any settings command (
destination:
PERM
time:
Length of insert in either
OK to omit on hours) OR in number of seconds. (A one-hour
parameters: of
source:
PERM
sets the value of individual parameters in a 'scratch pad' settings group.
SET
pad settings to a search table entry or to the permanent or temporary settings (requires an insert time as
a second parameter).
current or permanent settings.
SETAUDIO port route [program] [atten]
port:
Value of
route:
S - Stereo (Left and Right components routed as connected at original MPEG encoder)
1 - Original Left component to both L and R outputs
2 - Original Right component to both L and R outputs
M - Sum of Left and Right components to both L and R outputs
R - Reverse of "Stereo" above (if allowed by hardware)
program:
Can be a three character name or an '*'. If the 3-character name is specified, the unit will
route the audio PES stream with the specified name to the port. If ''*' is specified, the unit
will default to the first audio program in the PMT that is not routed to another port.
atten:
Must be a numeric value for attenuation in dB. Legal values are given in
page 3. This programs the net audio attenuation, where '0' gives 0dB attenuation
(maximum level). If field omitted, attenuation remains unchanged on that audio port.
The audio PES stream, with the language descriptor
and then its components are routed to the Left and Right outputs according to route. That ports
attenuation is changed to atten, if supplied.
SETLABEL label
label:
Unit label. Field entry is truncated at 10 characters.
Sets Unit Label displayed on IRD home LCD screen (and Terminal Welcome Banners), if supported in
this IRD.
www.wegener.com
,
, number or label of a Preset table entry.
TEMP
HH:MM:SS
or
1:00:00
3600
,
, number or label of a Preset table entry.
CURR
loads the scratch pad settings from a search table entry or from the
SET FROM
to
indicating an audio port
1
6
PERM
PERM
format (valid range is
.)
, is decompressed in the port audio port,
program
43
U
4600 U
'
M
NITY
SER
S
and
commands for
ADDE
,
,
, etc.)
TEMP
ADDS
to
, leading zeros
0:00:00
18:00:00
could have a
TEMP
will store the scratch
SET TO
Table 1.1
800032-01 Rev.F
ANUAL
on

Advertisement

Table of Contents
loading