Configure The Alarm Settings [Alarm]; Configure The Settings Relating To The Alarm Action [Alarm] - Panasonic WV-SP302 Operating Instructions Manual

Wvsp302 user guide
Hide thumbs Also See for WV-SP302:
Table of Contents

Advertisement

Configure the alarm settings [Alarm]

The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the VMD
area settings, and the alarm occurrence notification can be configured on this page.
The "Alarm" page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.

Configure the settings relating to the alarm action [Alarm]

Click the [Alarm] tab on the "Alarm" page. (☞ Pages 22 and 23: How to display/operate the setup menu)
The settings relating to the alarm can be configured in this section.
■ Alarm
[Terminal]
Determine how to use the terminals.
Alarm input: Receives alarms.
Black & white mode: Receives the black & white swi-
tchover input.(When the input is set to On, the black
& white mode is activated.)
Off: Not used.
Default: Off
Note:
• Refer to the installation guide for further information
about input/output terminals.
[VMD alarm]
When clicking "VMD >>", the [VMD area] tab of the
"Alarm" page will be displayed.
[Command alarm]
Select "On" or "Off" to determine whether or not to
receive the command alarm.
The command alarm is the function that provides notifi-
cation of a Panasonic protocol alarm from the other
cameras. When "On" is selected, alarm actions will be
performed between multiple cameras.
Default: Off
60
SP306
[Originating port number]
Select a port number to be used to receive the com-
mand alarm.
Available range: 1-65535
Default: 8181

Advertisement

Table of Contents
loading

Table of Contents