Savin 2555 Copy Reference Manual page 84

Document server
Hide thumbs Also See for 2555:
Table of Contents

Advertisement

ZBQP060E
Staple unit for Saddle Stitch function
1
2
R7
ZBQP070E
ZBQP080E
ZBQP090E
To initialize the staple unit with the User Tools (System Settings)
A Press the {User Tools/Counter} key.
B Press the [System Settings] key.
C Press the [Staple initialization] key on the "Basic Page 2" menu.
D Press the [OK] key.
• 6: Push the cartridge until it clicks.
• 7: Close the front cover of the finisher.
• 1: Open the front bottom cover of the
finisher.
• 2: Pull lever R7 and fully pull out the
staple unit.
• 3: While pulling the lever of the staple
unit, lift the lever of the staple unit.
• 4: Take out the empty cartridge.
• 5: Set the new cartridge.
• 6: Bring the staple unit back into place.
• 7: Close the front bottom cover of the
finisher.
d Adding Staples
291
5

Hide quick links:

Advertisement

Table of Contents
loading