6.35 Set relative horizontal position "<MOVX >"
Format:
<010Fxxxx>B
Range of Values for Parameters:
If F=0: -8 parameter 7
If F=1: counter value=1, 2
Parameter=n1 or n1 + n2 x 256
Function:
1)
The parameter shows the relative signed horizontal position from the current
printing position in the X direction.
The units may be specified as byte or dot units with the <MOVXBYTE> or
<MOVXDOT> command respectively. Directly after the input of the ESC .2
command, <MOVXDOT> is designated.
2)
Negative values are expressed in two's complement.
3)
The printing position in the X direction is set to (the present position) + (the
designated shift amount).
4)
A setting past the physical right margin is ignored.
5)
A setting past the physical left margin is ignored.
Initial State:
<MOVXDOT> is set.
Related Commands:
Commands related in the direction of applying an effect (Setting)
None
Commands related in the direction of receiving an effect (Setting)
None
Commands related in the direction of applying an effect (Operation)
None
Commands related in the direction of receiving an effect (Operation)
Byte units are set by the MOVXBYTE command.
Dot units are set by the MOVXDOT command.
EPSON Imaging Technology Center