MAINTENANCE

WARNING: HOT PARTS CAN CAUSE BURNS. USE CARE WHEN MAINTAINING THE BROILER.
BURNERS
If, after a period of satisfactory operation, burner flame characteristics should change or length of flame
should be reduced, burner ports may have become restricted. Burners should be cleaned at least every
60 days and more often if required. To clean burners, remove and boil in a strong solution of lye water
for about 15 minutes. Ports can be opened with a sharp-pointed instrument or proper-sized drill bit. Be
careful not to increase the size of the burner ports.
If the mixer openings or pilot orifices need cleaning, contact your Vulcan gas service technician. This
should be done at least every 6 months and more often if necessary.

SERVICE AND PARTS INFORMATION

To obtain service and parts information concerning this model, contact the Vulcan-Hart Service
Agency in your area (refer to our website, www.vulcanhart.com for a complete listing of Authorized
Service and Parts depots).
When calling for service, the following information must be available: model number, serial number,
manufacture date code (MD) and voltage.