General Information On Assembling Vent Pipes; Flex Vent Pipes - Temco 33RDVN Installation And Owner's Manual

Builder rear vent direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

RDVN Series Direct Vent Gas Fireplace
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
G =
Combustible
G
6" (152 mm)
Noncombustible
V
2" (51 mm)
Balcony -
with no side wall
M
V
M =
Combustible &
Noncombustible
12" (305 mm)
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3' (914 mm) minimum between termination caps. 2. All
mechanical air intakes within 10' (1 m) of a termination cap must be a minimum of 3' (914 mm) below the termination cap. 3. All
gravity air intakes within 3' (914 mm) of a termination cap must be a minimum of 1' (305 mm) below the termination cap.
Fig. 9 Termination clearances.
Canadian Installations:
The venting system must be installed in accordance
with the current CSA-B149 .1 installation code.
USA Installations:
The venting system must conform with local codes and/
or the current National Fuel Gas code ANSI Z223.1/
NFPA 54.
Only venting components manufactured by CFM Cor-
poration can be used in Direct Vent systems.

Flex Vent Pipes

Before joining the flex vent pipe to the unit, apply a
bead of high temperature sealant* (provided) to the 4"
pipe exiting the fireplace. Secure flex vent pipe in place
with a hose clamp (provided).
*Be sure the flex pipe overlaps at least 1" (25 mm) onto
the collars of the fireplace and termination. If the ter-
mination has an internal bead, be sure to overlap and
secure 1" (25 mm) past the bead.
12
Outside Corner
V
F
Balcony -
with perpendicular side wall
M
Combustible &
Noncombustible
M = 24" (610 mm)
P = 20" (508 mm)

General Information on Assembling Vent Pipes

Alcove Applications*
F =
Combustible
6" (152 mm)
Noncombustible
2" (51 mm)
of Caps
V
P
D
Min.
C
Max.
* Be sure the vent is actually crushed before proceed-
ing. Apply a tug to be sure the vent will not slip off the
collars.
Repeat process with 7" flex vent pipe. The same proce-
dure must be performed on the vent side.
Fig. 10 Apply high temperature sealant to 4" and 7" pipes.
D
C
C
V
E
O
E
= Min. 6" (152 mm) for
non-vinyl sidewalls
Min. 12" (305 mm) for
vinyl sidewalls
O
= 8' (2.4 m) Min.
No.
D
C
Min.
1
3' (914 mm)
2 x D
2
6' (1.8 m)
1 x D
3
9' (2.7 m)
2/3 x D
4
12' (3.7 m)
1/2 x D
= # of Termination caps x 3
= (2 / # termination caps) x D
Actual
Hose Clamp
Apply High Temperature
Sealant
FP1471
Max.
Actual
Actual
Actual
Actual
584-15
FP1471
20007628

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

36rdvn39rdvn

Table of Contents