Lamp Command; Cf_Lamph Command; Cf_Lampmode Command - Sanyo PLC-XK2200 - 2200 Lumens Manual

Rs232 expand
Hide thumbs Also See for PLC-XK2200 - 2200 Lumens:
Table of Contents

Advertisement

PLC-XK2200 /2600 /XK3010

8.8 Lamp Command

8.8.1

CF_LAMPH Command

Command
"CF_LAMPH_%1"[CR]
%1
"RST"
Reset total lamp running time
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.8.2

CF_LAMPMODE Command

Command
"CF_LAMPMODE_%1"[CR]
"HIGH" ------------ Set lamp to High mode status
"NORMAL" ------- Set lamp to Normal mode status
%1
"ECO" ------------- Set lamp to 3L mode status
"UP" --------------- The same operation as pressing Up key or Left key
"DN" --------------- The same operation as pressing Down key or Right key
Select Lamp Mode
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
Expand Serial Command Functional Specifications
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
34 / 73

Advertisement

Table of Contents
loading

Table of Contents