Cr_Tempfail Command - Sanyo PLC-XK2200 - 2200 Lumens Manual

Rs232 expand
Hide thumbs Also See for PLC-XK2200 - 2200 Lumens:
Table of Contents

Advertisement

PLC-XK2200 /2600 /XK3010
9.12.7

CR_TEMPFAIL Command

Command
"CR_TEMPFAIL"[CR]
Get the temperature inside a projector when abnormal temperature occurs.
Details
If there are several sensors installed, it is possible to get information from all the
sensors at once.
Acceptable
%a
Response
%b
%c
Unacceptable
Expand Serial Command Functional Specifications
"000_%a_%b_%c"[CR]
%a ------------------ Sensor 1 temp. (External temp.)
%b ------------------ Sensor 2 temp. (Internal temp.1)
%c ------------------ Sensor 3 temp. (Internal temp.2)
[Example]
"_31.5F"[CR]
"_" indicates a space. When the temperature sinks to -, the first
character is "-" like "-05.5F"[CR]
The last character means the sensor's status if it reaches
abnormal temperature
Exceeding critical temp. ------------------------------ "F"
Temp. is safe -------------------------------------------- "S"
Sensor detects no critical temp.--------------------- "N"
The example shows that sensor 1 indicates 31.5 degrees and the
temperature is abnormal.
When the temperature is safe, all data are represented as
"□000S".
When the projector is reset, "□000S" is set, and every time
abnormal temperature occurs, it renews the data and returns it.
In short, it only returns the renewed data of the latest abnormal
temperature and the previous data is deleted.
"Error Code" [CR]
73 / 73

Advertisement

Table of Contents
loading

Table of Contents