Lamp Status Read Command; Cr_Lamprepl Command; Cr_Lamph Command; Cr_Lampcorresph Command - Sanyo PLC-XK2200 - 2200 Lumens Manual

Rs232 expand
Hide thumbs Also See for PLC-XK2200 - 2200 Lumens:
Table of Contents

Advertisement

PLC-XK2200 /2600 /XK3010

9.9 Lamp Status Read Command

9.9.1

CR_LAMPREPL Command

Command
"CR_LAMPREPL"[CR]
Details
Get information of Lamp Replacement time
Acceptable
Response
%1
Unacceptable
9.9.2

CR_LAMPH Command

Command
"CR_LAMPH"[CR]
Get total running time of lamp by hour (h)
Details
*Actual running time, not corresponding value
Acceptable
Response
%1
Unacceptable
9.9.3

CR_LAMPCORRESPH Command

Command
"CR_LAMPCORRESPH"[CR]
Get total running time of lamp by hour (h)
Details
* Corresponding value, not actual running time
Acceptable
Response
%1
Unacceptable
9.9.4

CR_LAMPMODE Command

Command
"CR_LAMPMODE"[CR]
Details
Get setting status of Lamp Mode
Acceptable
Response
%1
Unacceptable
Expand Serial Command Functional Specifications
"000_%1"[CR]
"1Y" -------------------------- Over lamp replacement time
"1N" -------------------------- Within lamp replacement time
"1" means the number of lamps.
(1 lamp model→ "1")
"Y"/"N" means if it has reached its replacement time or not.
e.g. "1Y" -----------projector is 1 lamp model and Lamp is over its
replacement time
"Error Code"[CR]
"000_%1"[CR]
"00000"~"99999"
"Error Code"[CR]
"000_%1"[CR]
"00000"~"99999"
"Error Code"[CR]
"000_%1"[CR]
"HIGH" -------------------- Lamp Mode is High
"NORMAL" -------------- Lamp Mode is Normal
"ECO" --------------------- Lamp Mode is Eco
"Error Code"[CR]
61 / 73

Advertisement

Table of Contents
loading