The Battery; Battery Charger - Generac Power Systems 8KW Owner's Manual

8, 10, 12, 14, 16, 17 & 20kw air-cooled automatic standby generators
Hide thumbs Also See for 8KW:
Table of Contents

Advertisement

GENERAL
NFORMATON
Section 1 - Genera[ information
Air-cooled Generators
NOTE:
Dielectric
grease
should
be used
on battery
posts
to aid in the prevention
of corrosion.
NOTE:
Damage
will result
if battery
connections
are made
in reverse.
NOTE:
In areas
where
temperatures
regularly
fall below
10 ° F (-12 ° C) it is recommended
that
a pad type
battery
heater
be installed
to aid in cold
climate
starting.
1.14 THE BATTERY
Do not dispose of the battery
in a fire. The
battery
is capable of exploding.
/_
A battery
presents a risk of electrical
shock
and high short circuit current. The following
pre-
cautions
are to be observed when working
on
batteries:
* Remove the 7.5A fuse from the generator
control
panel.
, Remove watches,
rings or other metal objects;
, Use tools with
insulated handles;
* Wear rubber gloves and boots;
* Do not lay tools or metal parts on top of the
battery;
and
* Disconnect charging source prior to connecting or
disconnecting
battery terminals.
=_
WARNING
/_
Do not open or mutilate
the battery. Released
electrolyte
has been known to be harmful
to the
skin and eyes, and to be toxic.
/_
The electrolyte
is a dilute sulfuric
acid that is
harmful
to the skin and eyes. It is electrically
conductive
and corrosive.
The following
procedures are to be observed:
* Wear full eye protection and protective clothing;
* Where electrolyte
contacts the skin, wash it off
immediately with water;
* Where electrolyte
contacts the eyes, flush thor-
oughly
and immediately with water and seek
medical attention;
and
* Spilled electrolyte
is to be washed down with an
acid neutralizing
agent. A common
practice is to
use a solution
of 1 pound (500 grams) bicarbonate
of soda to I gallon (4 liters) of water. The bicar-
bonate of soda solution
is to be added until the
evidence of reaction (foaming)
has ceased. The
resulting
liquid is to be flushed with water and the
area dried.
t2
z_
Lead-acid batteries
present a risk of fire because
they generate
hydrogen
gas. The following
procedures are to be followed:
* DO NOT SMOKE when near the battery;
* DO NOT cause flame or spark in battery
area; and
* Discharge static electricity
from body before touch-
ing the battery
by first touching
a grounded
metal
surface.
/_
Be sure the AUTO/OFF/MANUAL
switch is set to
the OFF position before connecting
the battery
cables. If the switch is set to AUTO or MANUAL,
the generator
can crank and start as soon as the
battery
cables are connected.
Be sure the utility
power supply is turned
off
and the 7.5A fuse is removed from the genera=
tot control panel, or sparking
may occur at the
battery
posts as the cables are attached
and
cause an explosion.
Servicing
of the battery
is to be performed
or super-
vised
by personnel
knowledgeable
of batteries
and
the required
precautions.
Keep unauthorized
person-
nel away from batteries.
See
the
Specifications
section
for
the
correct
size
and
rating
when
replacing
the
battery.
Have
these
procedures
performed
at the
intervals
specified
in
the
'°Service
Schedule."
A negative
ground
system
is
used.
Battery
connections
are
shown
on the
wiring
diagrams.
Make
sure
the battery
is correctly
connect-
ed and
terminals
are
tight.
Observe
battery
polarity
when
connecting
the battery
to the generator
set.
1.15
BATTERY CHARGER
NOTE:
These
generators
DO NOT contain
an internal
bat-
tery charger.
NOTE:
The manufacturer
provides
a battery
trickle
char-
ger that
is active
when
the unit
is set up for auto-
matic
operation.
With
the
battery
installed
and
utility
power
source
voltage
available
to the trans-
fer switch,
the
battery
receives
a trickle
charge
to prevent
self-discharge.
The
trickle
charger
is
designed
to help
extend
the life of the battery
by
maintaining
the battery.
The trickle
charge
feature
cannot
be used
to recharge
a discharged
battery.
For units
shipped
with a transfer
switch/load
center_
the battery
charger
is pre-installed
in the transfer
switch
enclosure.
For units
shipped
without
a transfer
switch!load
cen-
ter,
a separate
battery
charger
module
is included
with
the generator.
(For battery
charger
installation,
see the Generator
Install
Guidelines
and Battery
Charger
Instructions
included
with the unit.)