Cooling System; Attentionaftersubmersion; Section 4 - Maintenance; Valve Clearance - Generac Power Systems 8KW Owner's Manual

8, 10, 12, 14, 16, 17 & 20kw air-cooled automatic standby generators
Hide thumbs Also See for 8KW:
Table of Contents

Advertisement

MAINTENANCE
Section 4 - Maintenance
Air-cooled Generators
, Make sure the piston
is at Top Dead Center
(TDC)
of its compression
stroke
(both valves
closed).
To
get the piston
at TDC, remove
the intake
screen
at
the front of the engine
to gain access
to the flywheel
nut. Use a large socket and socket wrench
to rotate
the nut and hence
the engine
in a clockwise
direc-
tion. While watching
the piston
through
the spark
plug hole. The piston
should
move up and down.
The piston
is at TDC when
it is at its highest
point
of travel.
To adjust
valve
clearance
(if necessary),
(Figure
4,9):
* Make sure the engine
is at 60 ° to 80 ° E
* Make
sure
that
the spark
plug wire
is removed
from the spark
plug and out of the way.
. Remove
the four screws
attaching
the valve cover.
. Loosen
the rocker
jam
nut.
Use an
10ram
allen
wrench
to turn
the pivot ball stud while checking
clearance
between
the rocker
arm
and
the valve
stem
with
a feeler
gauge.
Correct
clearance
is
0.002-0.004
inch (0.05-0.1
ram).
Figure
4.9 - Valve
Clearance
Adjustment
Jam Nut
Pivot Ball
Stud
Rocker
Arm
Valve
Stem
* Install
spark
plugs.
* Re-attach
the spark
plug wire to the spark
plug.
. On the GT-530 and GT-990/999,
repeat
the process
for the other
cylinder.
4.8
COOLING SYSTEM
Air inlet and
outlet
openings
in the generator
com-
partment
must
be open
and
unobstructed
for con-
tinued
proper
operation.
This includes
such
obstruc-
tions as high grass,
weeds,
brush,
leaves
and snow.
Without
sufficient
cooling
and
ventilating
air flow, the
engine/generator
quickly
overheats,
which
causes
it
to quickly
shut
down.
(See
Figure
4.10
for vent
loca-
tions.)
Make
sure
the
doors
and
roof
are
in place
dur-
ing operation
as running
the generator
with
them
removed
can effect cooling
air movement.
Figure
4.10 - Cooling
Vent Locations
NOTE:
Hold the rocker
arm jam
nut in place
as the pivot
ball
stud is turned.
When
valve
clearance
is correct,
hold
the
pivot
ball
stud
in place
with
the
allen
wrench
and
tighten
the
rocker
arm
jam
nut.
Tighten
the jam
nut
to
174
in!
lbs.
torque.
After
tightening
the
jam
nut,
recheck
valve
clearance
to make
sure
it did
not
change.
. Install
new valve cover gasket.
. Re-attach
the valve cover.
NOTE:
Start all four screws
before
tightening
or it will not
be
possible
to get all the
screws
in place,
Make
sure the valve
cover
gasket
is in place,
26
"_
WARNING
_-
Z_ The exhaust from this product gets extremely
hot and remains hot after shutdown. High grass,
weeds, brush, leaves, etc. must remain clear of
the exhaust. Such materials
may ignite and burn
from the heat of the exhaust system.
-A CAUT!ON
A-
Z_ The maximum
ambient
temperature
for the gen-
erator is 25 ° C (77 ° F).
4.9
ATTENTIONAFTERSUBMERSION
If the generator
has been submerged
in water,
it must
not be started
and operated.
Following
any submer-
sion
in water,
have
a Dealer
thoroughly
clean,
dry
and inspect
the generator.
If the structure
(ex. home)
has been
flooded,
it should
be inspected
by a certi-
fied electrician
to ensure
there won't be any electrical
problems
during
generator
operation
or when
utility
is returned.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

14kw20kw17kw10kw12kw16kw

Table of Contents