MAINTENANCE
Section 4 - Maintenance
Air-cooled Generators
3.6.3
MAINTENANCE ALERTS (10 = 20KW
ONLY)
Third
priority
+
Maintenance Message
When
a maintenance
period
expires,
a warning
mes-
sage will be displayed.
(16 through
20kW
models
include
an external
yellow LED which will illuminate.)
The
alert
can be reset
by pressing
the
Enter
key,
which
will cause the user to be prompted
to confirm
the action.
Resetting
will clear the alert and reset the
maintenance
counters
for all conditions
annunciated.
The history
log will record
the alert. The maintenance
counter
will not
accumulate
without
battery
power.
Once battery
power
is restored,
the set time prompt
will be displayed.
The maintenance
counters
will be
adjusted
to the new time and date.
NOTE:
Since
most
maintenance
alerts
will occur
at the
same
time
(most
have
two (2) year
intervals),
only
one
will appear
on the
display
at any
one
time.
Once the first
alert
is cleared,
the next
active
alert
will be displayed.
4.1
FUSE
The
7.5 amp
fuse on the control
panel
protects
the
DC control
circuit
against
overload
(Figures
3.1 and
3.2). This fuse is wired
in series
with the battery
out-
put lead to the panel.
If this fuse element
has melted
open,
the engine
will not be able to crank
or start.
Replace
this
fuse
using
only an identical
7.5
amp
replacement
fuse.
Whenever
the fuse is removed
or
replaced,
the exercise
timer
needs
to be reset.
4.2
CHECKING THE ENGINE
OIL LEVEL
For
oil capacities,
see
the
Specifications
section.
For engine
oil recommendations,
see the Engine
Oil
Recommendations
section.
To check
the engine
oil
level, proceed
as follows
(Figures
4.1, 4.2 and 4.3):
1.
Move the AUTO/OFF/MANUAL
switch
to the OFF
position.
2.
Remove
the dipstick
and wipe it dry with a clean
cloth.
3.
Completely
insert
the
dipstick;
then,
remove
it
again. The oil level should
be at the dipstick
"Full"
mark.
If necessary,
add
oil to the
'°Full" mark
only. DO NOT FILL ABOVE THE "FULE' MARK.
"_
CAUTION
/_
Never operate the engine with the oil level
below the "Add"
mark on the dipstick.
Doing
this could damage the engine.
22
4.
Install
the dipstick.
5.
Reset
the AUTO/OFF/MANUAL
switch
to its origi-
nal position,
Figure
4.1 -- Oil Dipstick
and Fill, 8kW
Dipstick and Fill
Figure
4.2 -- Oil Dipstick,
lOkW
Figure
4.3 -- Oil Dipstick
and Fill,
12, 14, 16, 17 & 20kW

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

14kw20kw17kw10kw12kw16kw

Table of Contents