Carrier Expressions 38CS030 Owner's Manual

Wall console/underceiling duct free systems

Advertisement

OWNER'S
MANUAL
38CG,CS018-030
40CG,CS018-030
Wall
Console/Underceiling
Duct
Free
Systems
CONTENTS
Page
INTRODUCTION
.................................
2
GENERAL .......................................
2,3
OPERATING MODES ............................
2
REMOTE CONTROL .............................
2
OPERATION
...................................
3-7
REMOTE CONTROL OPERATION ................
3
UNIT OPERATION ...............................
7
(;LEANING
AND MAINTENANCE
...............
7,8
AIR FILTERS ....................................
7
Page
INDOOR UNIT FRONT PANEL ...................
7
INDOOR UNIT COIL ............................
7
OUTDOOR UNIT COIL ..........................
8
CONDENSATE DRAINS .........................
8
SYSTEM OPERATION CHECK LIST ..............
8
DIP SWITCH SETTINGS .........................
8
ENERGY SAVING RECOMMENDATIONS
.........
8
TROUBLESHOOTING
GUIDE ....................
9
Manufacturer reserves the right to discontinue, or change at any time, specifications
or designs without notice and without incurring obligations.
PC 111
Catalog
No, 533-80052
Printed in U.S.A.
Form OM38/40-2
Pg 1
2-02
Replaces:
OM38/40-1

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Expressions 38CS030

  • Page 1 OWNER'S MANUAL 38CG,CS018-030 40CG,CS018-030 Console/Underceiling Systems Wall Duct Free CONTENTS Page Page INTRODUCTION ......... INDOOR UNIT FRONT PANEL ....INDOOR UNIT COIL ......GENERAL ........OUTDOOR UNIT COIL ......OPERATING MODES ......CONDENSATE DRAINS ......REMOTE CONTROL ......SYSTEM OPERATION CHECK LIST ....OPERATION ........
  • Page 2 INTRODUCTION FAN ONLY In Fro1 Only mode, the system filters and cir- culates rooln air without chanNng room air telnperamre. Thank you for choosing an Expressions Duct Free System. HEATING In Heating mode, the system heats and filters The stone pride in craftsmanship and enNneering knowledge air.
  • Page 3: Operation

    The relnote control cml pertbnn the following functions: NOTE: When translnitting a colrnnand tiom the controller to the unit, be sure to point the controller toward the right side of • Turn the system ON and OFF the unit. See Fig. 4. The unit wilt contirln receipt of a com- •...
  • Page 4 INFRARED SIGNALTRANSMITTER WINDOW SENSOR CLOCK-_-_ INDICATOR LOW BATTERY INDICATOR TIMER START/STOP ONE-TIME/DAILY INDICATORS UP/DOWN BUTTON MODE BUTTON OPERATION MODE INDICATORS COOLING, FAN, HEATING, DEHUMIDIFICATION AUTO SENSOR ACTIVE INDICATOR FAN INDICATORS LOW, MEDIUM, HIGH, AUTO SWEEP INDICATOR TIMER SET BUTTONS* ROOM TEMPERATURE BUTTON* BUTTON* SLIDE DOWN PANEL...
  • Page 5 2. Press the TIMER button. Each time the button is pressed the next Start or Stop set thne appears on the display. See Fig. 6. SLEEP ..TOP 1720 TIMER 3. Press UP/DOWN button to set the time. INDICATOR i_SLEEP ..
  • Page 6 To set Local Sense function: 11:% 1. Slide down tiont cover of controller below ON/OFF button. See Fig. 4..+J? sToP 2. Press the SENSE button. The "House" s3anbol will ap- DAILY D A _ LY TIMER ..pear on the display screen. See Fig. 12. INDICATOR 3.
  • Page 7: Turn Unit On

    Unit Operation (Fig. 13 and 14) -- The system can UNIT OPERATION SWITCH be operated froln the unit in the evem the relnote control is not working or is misplaced. TURN UNIT ON Slide the Operation Switch on the unit to the Auro position.
  • Page 8 DIP Switch Settings- remote control contains seven DIP switches, located in the battery comparnnent, t_xs_ of which control special system characteristics. See Fig. 16. The DIP switch default positions are set according to the model air coMitioner installed, as per the folbwing table. SWITCH POSITION Switch No.
  • Page 9: Troubleshooting

    TROUBLESHOOTING GUIDE Refer to the Troubleshooting Guide below bet_)re contacting your local deaten PROBLEM POSSIBLE CAUSE SOLUTION • No command transmitted to unit. • Press the ON/OFF button. Unit/system does not work • Unit did not receive transmitted command. • Make sure that remote control is pointed at unit during command transmission.
  • Page 10 Dealer's Name Addl_ess Purchase Telephone Indoor Model # Outdoor Model # Indoor Serial # Outdoor Serial #...
  • Page 12 Copyright 2002 Carrier Corporation Manufacturer reserves the right to discontinue_ or change at any time, specifications or designs without notice and without incurring obligations, PC 111 Catalog No. 533-80052 Printed in U,S.A. Form OM38/40-2 Pg 12 2-02 Replaces: OM38/40-1...

Table of Contents