INSTALLING YOUR REFRIGERATED DRAWERS
Select Location
The proper location will ensure peak performance of your ap-
pliance. We recommend a location where the unit will be out
of direct sunlight and away from heat sources. To assure your
product performs to specifications the recommended installation
location temperature range is from 55 to 100°F (13 to 38°C).
Cabinet Clearance
Ventilation is required from the bottom front section of the unit.
Keep this area open and clear of any obstructions. Adjacent
cabinets and counter top can be installed around the unit as long
as the grille and drawer access remain unobstructed.
Front Grille
Do not obstruct the front grille. The openings within the front
grille provide air to flow into and exit from the refrigerator
condenser. For this reason it is important this area to not be ob-
structed and be kept clean. AGA MARVEL does not recommend
the use of custom made grilles as air flow may be restricted
because of inadequate openings. (See Figure 1).
Figure 1
3
Front Grille, keep
this
area open.

Leveling Legs

Leveling Legs
Adjustable legs at the front and rear corners of the unit should
be set so the unit is firmly positioned on the floor and level from
side to side and front to back. Turn leveling legs clockwise to
raise unit, counterclockwise to lower it. (See Figure 1).
Do not splash or spray water from a hose on the refrigera-
tor! Doing so may cause an electrical shock, which may
result in severe injury or death.
This unit should not, under any circumstances, be un-
grounded.

Grounding Method

This product is factory equipped with a power supply cord that
has a three-pronged, grounded plug. It must be plugged into a
mating grounding type receptacle in accordance with the Na-
tional Electrical Code and applicable local codes and ordinances
(see Figure 2). If the circuit does not have a grounding type re-
ceptacle, it is the responsibility and obligation of the customer to
exchange the existing receptacle in accordance with the National
Electrical Code and applicable local codes and ordinances. The
third ground prong should not, under any circumstances, be cut
or removed.
Electrical Connection
115 volts, 3.3 amps running max. A 15 amp dedicated circuit is
required. A 3 prong grounded receptacle is required.
Do not use an extension cord with
this appliance.
Figure 2