Troubleshooting Guide - AGA marvel 60RDE Installation And Maintenance Instructions Manual

Refrigerated drawer
Table of Contents

Advertisement

Before You Call for Service
If the unit appears to be malfunctioning, read through this
manual first. If the problem persists, check the troubleshooting
guide below. Locate the problem in the guide and refer to the
cause and its remedy before calling for service. The problem may
be something very simple that can be solved without a service
call. Some remedies listed in the Troubleshooting Guide are very
complex. Consulting or contracting a qualified service technician
may be necessary.
Electrocution Hazard - Never attempt to repair or perform main-
tenance on the unit until the main electrical power has been
disconnected.
Problem
Unit not cold enough.
Unit too cold.
No interior light in drawer compartments.
Light will not go out when drawer is
closed.
Noise or Vibration.
Unit will not run.
TROUBLESHOOTING YOUR REFRIGERATED DRAWERS
Possible Cause
Control set too warm.
Airflow to front grille blocked.
Excessive usage or prolonged drawer
openings.
Drawer gasket not sealing properly.
Control set too cold.
Failed LED interior light assembly.
Drawer not activating light switch.
Unit not level.
Unit turned off.
Power cord not plugged in.
No power at outlet.
Remedy
Adjust temperature colder. (See "Set
the desired temperature" on page 6).
Allow 24 hours for temperature to
stabilize.
Airflow must not be obstructed to
front grille. See "clearances" on page
3.
Allow temperature to stabilize for at
least 24 hours.
Adjust or replace drawer gasket.
Adjust temperature warmer. (See
page 6, "set the desired tempera-
ture"). Allow 24 hours for tempera-
ture to stabilize.
Contact a qualified AGA MARVEL
service technician.
Unit not level, level unit, (See page 3,
"leveling legs")
Level unit, see "Leveling Legs" on
page 3.
Turn unit on. See "Start your Appli-
ance" on page 6.
Plug in power cord.
Check house circuit.