Exhaust Blower Ratings - GE JP989 Owner's Manual & Installation Instructions

Radiant downdraft
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
EXHAUST BLOWER RATINGS
45O
EXHAUST BLOWER SAFETY WARNING
Sufficient
air is needed for proper combustion
and exhausting
of gases through
the flue
(chimney)
of other fuel burning equipment
to prevent back drafting.
Follow the heating
equipment
manufacturer's
guidelines
and safety standards
such as those published
by
the National Fire Protection
Association
(NFPA), the American
Society for Heating,
Refrigeration
and Air Conditioning
Engineers (ASHRAE) and local code authorities.
NOTE: The exhaust
blower
output
is approximately
400 CFM (cubic feet per minute)
without
ductwork.
Each installation
is different
and ductwork
affects
blower
output
accordingly.
Actual
blower
exhaust
CFM can be approximated
using the graph below.
Step 1: Calculate
the "equivalent
duct length"
using the "DUCTWORK
CALCULATIONS"
table in these instructions
for your installation.
Step 2: Find the approximate
intersection
point
of the blower
exhaust
performance
curve with the equivalent
duct length
to estimate
the actual
maximum
blower
output
for your
installation.
Examples:
50 equivalent
feet of ductwork
has approximately
320 CFM.
100 equivalent
feet of ductwork
has approximately
265 CFM.
Downdraft
Cooktop
Exhaust
Blower
CFM
g.
O
g.
,m
<[
350
300
25O
200
150
100
50
25
50
75
100
125
6" Diameter
Equivalent
Duct Length
150
19

Advertisement

Table of Contents
loading

Table of Contents