GE JP989 Owner's Manual & Installation Instructions page 17

Radiant downdraft
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
CABINET PREPARATION CUTOUTS
[] PREPARING THE COUNTERTOP
The countertop
must
have a deep flat surface
to accommodate
the cooktop
and the vent.
Countertops
with
a rolled
front
edge and
backsplash
may not provide
the flat surface
area required.
Clearance
between
inside
front
of cabinet
and
rear of countertop
cutout
must
be 20%" in
order to accommodate
cooktop
depth.
2%" Min.
1%" Min.
A 1/2" wide
flat area is required
around
the
edge of opening
for support
of the unit. The
cooktop
unit must
be level
and sit squarely
into countertop
opening.
Carefully
cut countertop
opening
according
to
the dimensions
shown
in the illustration.
Be
sure that opening
is cut squarely,
with
sides
parallel
to each other
and rear exactly
perpendicular
to sides.
20%"
17_" Min.
[] PREPARINGFOR DUCTWORK
NOTE: Ductwork MUST be vented to outside. DO
NOT vent into a wall, ceiling, crawlspace, attic or any
concealed space.
Cut hole in cabinet wall or floor as appropriate for
your installation. Make sure exhaust duct is located
between wall studs or floor joists.
NOTE: When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other hidden
utilities.
91/3"
183/4 "
Rear Wall Venting
Downward
Venting
[] BLOWER TO DUCTWORK ALIGNMENT
In general, the use of flexible ducting is discouraged
because it can cause severely restricted airflow.
However, if the blower outlet and the floor or wall
duct location do NOT align well, then flexible METAL
ducting can be used to adapt to an offset. Good
alignment without
use of flexible ducting is best.
NOTE:
• Do not exceed the maximum
recommended
offset
of 6".
* Do not allow the flexible ducting to kink or collapse.
* Do stretch the flexible ducting as much as possible
to eliminate as much of the corrugation as possible.
_6"Max._
i
Centtejline_
I
Ce_F:_it
e t
Bottom
Venting
Back Venting
(Requires
31¼" x 10")
A 31A'x 10" rectangle to 6" round transition duct is
available at your local building supply store.
NOTE: Illustrations
are for planning purposes only.
17