DUCTWORK CALCULATIONS
Calculate
Total E(
Duct Pieces
6" round
straight
31/4" x 10"
straight
C_
6", 90 °
elbow
6", 45 °
elbow
24" max.
flexible
metal offset
adapter
31/4,,X10,
"
90 ° elbow
31/4"
X
10"
45 ° elbow
31/4,,X10,
"
90° flat elbow
6" round
to 31/4 " x 10"
transition
uivalent
Ductwork
Length
Equivalent
Number
Length*
x
Used
=
1 ft.
x
(
)*=
1 ft.
x
(
F=
15 ft.
x
(
) =
9ft.
x
(
)=
34 ft.
x
(
)=
16 ft.
x
(
) =
5ft.
x
(
)=
18 ft.
x
(
)=
7ft.
x
(
)=
Subtotal
Column
1 =
Equivalent
Length
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
ft.
*Equivalent
lengths of duct pieces are based on
actual tests and reflect requirements
for good
venting
performance
with any downdraft
cooktop.
tMeasure
and list feet of straight
duct used. Count
and list the quantity
of all other duct pieces for
the "Number
Used" of each type.
IMPORTANT:
For maximum
efficiency,
use the shortest and
straightest
duct run possible, with as few fittings
as possible.
For satisfactory performance, the duct
run should not exceed 100 feet equivalent length.
Venting performance
is improved
by using larger
diameter duct.
Equivalent
Number
Equivalent
Duct Pieces
Length*
x
Used
=
Length
6" round
to 31/4 " x 10"
transition
90 ° elbow
20 ft.
x
(
) =
ft.
31/4" x 10"
to 6" round
transition
5 ft.
x
(
) =
ft.
[_
31/4"
X
10"
to 6" round
transition
90 ° elbow
12 ft.
x
(
)=
ft.
6" round
wall cap
with damper
21 ft.
x
(
) =
ft.
31/4"
X
10"
wall cap
with damper
27 ft.
x
(
) =
ft.
6" round
roof cap
20 ft.
x
(
) =
ft.
6" round
roof vent
24 ft.
x
(
) =
Subtotal
Column
2 =
Subtotal
Column
1 =
TOTAL DUCTWORK
=
ft,
ft.
ft.
ft.
Should
not exceed
100 feet,
DO NOT use flexible
plastic
ducting.
Vent installation
should
not exceed
100 feet
equivalent
length.