Circuit Board Functions - England's Stove Works 10-CPM Installation & Operation Manual

Table of Contents

Advertisement

COMPONENT
Exhaust Blower
Starts Immediately.
(Combustion)
Stirrer
Three minutes after starting, the Stirrer
will begin to turn.
Auger
When starting, the auger will begin to
turn.
Room Fan
Begins when 110 degrees is reached.
(Convection)
Automatic
If, after 15 minutes, the unit has not
Shutdown
reached the preset operating temp., the
unit will begin to automatically shut
down. This will be evidenced by the red
light on the Control Board.
Normal Operation
If, after 15 minutes, the preset operating
temperature of 110 degrees is achieved,
normal operation will continue.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE
TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
Illustration 7 Control Board Diagram (Wiring)

CIRCUIT BOARD FUNCTIONS

OPERATION START
OPERATION END
Will continue until shutdown.
occur when the operating temperature is below
90 degrees.
Will continue intermittently, as determined by the
Heat Setting, until Shutdown
The auger will continue at the feed rate
determined by the Heat Setting. NOTE: Safety
switch, Hi Limit and Vacuum Sensor must be
activated to continue proper operation.
Will continue to operate until the unit cools down
to below 90 degrees.
several minutes up to an hour.
If the timer should expire before the preset
operating temperature is achieved, resetting the
timer is possible by switching the Control Board
"OFF" and then back "ON."
Operation will continue until either the Control
Board is turned "OFF," or the operating
temperature falls to below 90 degrees. At this
time,
the
unit
Shutdown."
25
Shutdown will
This may take from
will
default
to
"Automatic